Rosemount TankRadar Rex is a state-of-the-art inventory and custody transfer radar tank gauging system for storage tanks. It fulfills the highest requirements on performance and safety. The development of Rosemount TankRadar Rex is based on 25 years experience in radar level gauging. More than 50,000 radar gauges have been delivered by Rosemount.
 
APPLICATIONS
The Rosemount TankRadar Rex System can be used at bulk liquid storage tanks at refineries, independent tank terminals, marketing terminals, pipeline terminals, petrochemical industry, liquified gas terminals, and aviation fuel deposits.
 
The extensive range of TankRadar Rex 3900 Series level gauges fits all types of tanks, fixed or floating roofs, pressurized or non-pressurized. The Rosemount TankRadar Rex system measures the entire storage tank site.
 
The system software can also make accurate measurement and calculation of liquid levels, temperature and water interface level, hydrostatic and vapour pressure, and observed density, and TOV, GOV, GSV and NSV.
 
With a lean and clean installation, the Rosemount TankRadar Rex system offers also flexible field communication via many protocols eg, Profibus, Tiway, TRL/2. Intelligent gauge emulation compatible with all major tank gauging systems is also available.
 
SYSTEM OVERVIEW
 
GENERAL TECHNICAL DATA
Instrument Accuracy: ± 0.5mm (±5/256 inch)
Maximum instrument deviation: ± 0.8mm (± 1/32 inch)
Ambient operating temperature: -40°C to +70°C (-40°F to +158°F)
Hazardous locations certifications: II 1/2 G EEx d[ia] IIB T6 (T amb -40°C to 70°C) according to ATEX directive (EN 50014, EN 50018, EN 50020, EN 50284 Europe) and Class 1, Div 1, Groups C and D according to UL (UL1203, UL 913 and UL 508) for USA
See also Rosemount TankRadar Rex Technical Description. Ingress protection: IP 66 & 67
Housing material: Anodized aluminium
Power Supply: 100-240 VAC, 34-70 VAC (option), 20-78 VDC (option), 48-99 VDC (option).
Analog outputs: One output, 4-20 mA passive or active (non-intrinsically safe)
Analog inputs: alt 1) One or two 4-20 mA alt 2) One 4-20 mA input plus one digital HART input (the RTG is HART master. Each RTG can have maximum 3 HART slaves).
Relay outputs: Max 2 relays, only one output available if analog outputs are included.
Field bus (standard): TRL/2 Bus
Field bus (options):
  • Enraf ® (requires special Field Bus Modem, EBM)
  • Varec ® (only one relay available, analog output not available)
  • L&J ® (only one relay available, analog output not available)
  • Whessoe ® (only one relay available, analog output not available)
  • GPE ® (only one relay available, analog output not available)
  • Sakura ® (only one relay available, analog output not available)
Temperature inputs: Up to 6 temperature inputs (PT 100) with common return or 3 with individual wiring directly into the gauge. Up to 14 temperature inputs to each gauge via separate Data Acquistion Unit (DAU).
Temperature conversion accuracy: ± 0.1°C for -50°C to +250°C (-58°F to +482°F)
Note! Temperature range for PTB approval is -20°C to +90°C (-4°F to +194°F)
Total weight for transmitter head without flange: 12 kg (26 lbs)
Field data display: In separate DAU or RDU
Antennas: All antennas are of drip-off type in accordance with API


(Ch 3.1 B, Ed 1) For antenna specific data, see Technical Data for the different gauges (choose component).


For further information, see Rosemount TankRadar Rex Technical Description.
 
PRODUCTS
Rosemount TankRadar Pro Gauge Series
 
RTG 3920 Horn Antenna Gauge
 
The Horn Antenna Gauge is designed for easy mounting in small size openings on tanks with fixed roof. It can be mounted in a nozzle with a diameter of 8" (200mm) or larger.
 
Instrument Accuracy: ± 0.5mm (1/32")
Operating temp. in tank: Max. +230°C
Measuring range: 0.85 to 20 m(2.7 to 65 ft.) below flange
Pressure: -0.2 to 2 bar (-3 to 30 PSI)
Total weight: Approx. 20 kg (44 lbs)
Material exposed to tank atmosphere: Acid proof steel (type 316), PTFE (Teflon) and FPM (Viton)
Nozzle diameter
: Min. 8"

 
RTG 3930 Horn Antenna Gauge
 
The RTG 3930 gauge is designed for mounting on tanks with fixed roofs. It measures levels of products ranging from clean products to very difficult ones like bitumen/asphalt.
 
The Paraholic Antenna Gauge can also be used on tanks with floating roofs. The RTG is mounted at the tank top and measures the distance down to a target plate on the floating roof.
 
Instrument Accuracy: ± 0.5mm (1/32")
Operating temp. in tankMax.: +230°C
Measuring range
: 0.8 to 40 m (2.7 to 131 ft.) below flange
Pressure
: -0.2 to 0.2 bar (-3 to 3 PSI) option up to 10 bars (145 PSI)
Total weight: Approx. 25 kg (55 lbs)
Material exposed to tank atmosphere: Acid proof steel (type 316), PTFE (Teflon)
Nozzle diameter
: Min. 20"

 
RTG 3950 Still-Pipe Array Antenna Gauge
 
2 versions available:
- Inclined
- Fixed
 
RTG 3950 with its small-sized array antenna is made for mounting on existing still-pipes. Typical applications are crude oil tanks with floating roofs and gasoline/product tanks with or without inner floating tanks.
 
There are two versions of RTG 3950; fixed and inclined. The inclined version has a hinged hatch, enabling full pipe size product sampling or verification hand-dips.
 
Instrument Accuracy: ± 0.5 mm (1/32")
Operating temp. in tank: Max. -40°C to +120°C
Measuring range: 0.8 to 40 m (2.7 to 131 ft.) from antenna end
PressureFixed version: 2 bar (29 psig) at 20°C
Incline version: 5 to 8 inch pipes, 0.5 bar, 10 and 12 inch pipes, 0.25 bar (3.6 psig)
Total weight: 21.5 - 32 kg for fixed version, 28.5 - 41.5 kg for inclined version
Material exposed to tank atmosphere: Antenna: PPS
     Sealing: PTFE (Teflon)
     O-ring: Fluorosilicone
    Flange: Acid proof steel (type 316)
Still-pipe dimensions: 5-, 6-, 8-, 10-, or 12-inch

 
RTG 3960 LPG/LNG Gauge
 
The RTG 3960 gauge is designed for level management of liquefied gas in LPG or LNG tanks with still-pipes. The still-pipes enable the gauge to have a sufficiently strong echo even under surface boiling conditions.
 
Instrument Accuracy: ± 0.5 mm (1/32")
Operating temp. in tank
:-55°C to 90°C (-67°F to 194°C)
Measuring range: 0.5 to 60 mm (1.6 to 200 ft.) from cone end
Pressure: Up to 25 bar (365 PSI)
Pressure sensor: Druck PTX 621
Flange: 6"
Still pipe dimension: 4" sch. 10 or sch. 40 100 mm (99 mm inner diameter)
Total weight: 6" 150 PSI - appr. 38 kg (84 lbs)
6" 300 PSI - appr. 106 lbs)
Material exposed to tank atmosphere: Antenna: Acid proof steel (type 316) and quartz
                Sealing: Quartz

 
FCU 2165/2175 Field Communication Unit (FCU)
 
The Field Communication Unit (FCU) is a data concentrator that continuously polls data from field such as radar and servo tank gauges from different vendors data acquisition units, I/O Modules, other FCU:s, Enraf ® CIUS:s and hosts/ DCS systems such as Enraf ® Entis, Yokogawa ®, ABB ®, Honeywell ®, Foxboro ® etc.
 
Explosion protection: None
Ambient operating temperature
: -40°C to +70°C (-40°F to +158°F)
Power Supply: 115 or 230 VAC, +10% to -15%. 50-60 Hz
Power Consumption: 25 W (FCU 2165), 60 W (FCU 2175)
Ingress protection: IP 65 (FCU 2165), IP 21 (FCU 2175)
Field bus / Host ports: TRL/2 Bus, Enraf BPM, Whessoe Current Loop, RS232, RS422, RS485
Bus baudrate: Programmable up to 38400
Total number of RTG:s and Independent DAU:s per field bus port: Host dependent
Number of tanks per FCU: Host dependent 8

 
Lite, Standard, Gold and Platinum Transmitter Head Versions
 
TankRadar ® PRO is used for reliable level and volume measurement in refineries and tank terminals, where the demands on the accuracy of measurements are not so stringent.
 
The TankRadar Pro gauge is available in four versions for various requirements:
 
Lite
For non-hazardous area tanks without internal structures and agitators, such as storage tanks. Accuracy is ± 10 mm.
 
Gold
For difficult applications in tanks or vessels where there might be multiple agitators, heating coils, beams or other sources of false echoes and where high accuracy and resolution is required. Accuracy is ± 5 mm.
 
Platinum
Platinum is the TankRadar Pro version with the highest accuracy, of ± 3 mm. It includes the FHAST™ software and selected hardware for maximum performance.
 
Operating principle: 10 GHz FMCW-radar
Instrument accuracy: ± 3 mm (± 0.12 in.), ± 5 mm (± 0.2 in.) or ± 10 mm (± 0.4 in.) depending on model
Power supply: Ultra wide 24-240V DC or AC 0-60 Hz
Display/Configuration: Local display, remote display, RadarMaster PC software
Primary output: Rosemount TRL/2 bus (FSK with Modbus protocol) or Profibus ® DP, analog 4-20 mA, active or passive + digital HART ®, FOUNDATION ™ fieldbus
Secondary output: Analog 4-20 mA current loop, active or passive
Temperature measurement: Up to 6 spot elements per tank with common return, PT100 via display unit
Antennas: Cone, parabolic, process seal and still-pipe cone
Antennas materials wetted parts: Stainless steel SS 316L, PTFE, Quartz, Viton, Kalrez
Tank temperature: -40 to 400°C (-40 to 752°C)
Ambient temp.: -40 to 70°C (-40 to 158°C)
Measuring range: 0-50 m (0-165 ft.) default, 0-99 m (0-325 ft.) special configuration
Ex approval: ATEX/CENELEC: II I/2G / EEx de [ib/ia] IIC T6
FM: Explosion proof Class I, Div. 1 & 2, Groups A, B, C and D.
CSA: EEx de IIC T6. FTZU: EEx de ib IIC T6.
GOST: EEx de ib [ia/ib] IIC T4.
Weight: 8 kg (18 lbs.)
 
DOWNLOADS
Product Sheet, Reliable Leakage Detection
Product Sheet, Rosemount Tank Gauging System with Foundation ® fieldbus

 
More information are available at http://www.rosemount-tankradar.com/tankgauging_index.aspx.


Home | About Us | Products | Services | Events | Career | Contact Us
Copyright 2009 © All Rights Reserved. Gauging & Automation Pte Ltd 2009
Tel: (65) 6841 2866 | Fax: (65) 6841 1557