SITRANS F US ultrasonic flowmeters are used with homogenous conductive and non-conductive liquids. In addition to standard volume flow, ultrasonic flowmeters can provide information on media quality and temperature. Meter calibration can be certified to industry standards. |
| |
|
Siemens Controlotron’s Clamp-On Transit-Time Ultrasonic Flowmeters have been field installed in critical applications globally since the early 1970’s. Experience, reliability, and innovative use of technology set our products apart. Patented Wide-Beam™ Transit-Time and Reflexor™ technologies assure accurate reading even in difficult applications. Being non-intrusive is the key to universal applicability to all industries.
The Highly Reliable 1010 Product Family Features:
- Accurate flow measurement regardless of liquid type or temperature
- Operation with up to 50% aeration and indication of aeration presence
- Resistance to Aberrated Flow Profile and Crossflow errors
- Continuous Automatic Zero adjustment to prevent Zero drift
- Full installation without cutting pipeline or stopping flow
- Sonic identification of product type and quality
- Conventional digital and analog data outputs
- Direct interchangeability with conventional intrusive flowmeters
- Excellent cost efficiency
The differences between Siemens Controlotron and other competitive ultrasonic instruments are substantial. One component of the reason for this is the large number of Patents owned and used by Siemens Controlotron.
Siemens Controlotron vs ultrasonic (other clamp-on and insert type) flowmeters:
Other ultrasonic flowmeters use transducers with fixed frequencies, which experience cancellation as they transmit through the pipe wall of a mismatched frequency. Since the pipe wall acts as an obstacle to the beam, insert type flowmeters are popular as the beams are transmitted without passing through the pipe wall. However, insert type sensors require many paths as the beams are small and sample a small percentage of flow volume. Insert type sensors are also inline type, requiring downtime.
Siemens Controlotron’s Wide Beam has the following advantages:
- Matches transducer frequency to pipe, transforms pipe into sensor
- Low Voltage (+/- 15V) vs. 300+V in others
- Application Diagnostics & Tolerance – senses pipe build-up, up to 50% aeration in liquids, moisture or wet gas, hydrate detection
- Pico-seconds time resolution – allows measurement of lower flows and smaller pipes
- No Pressure Drop or Energy Loss (non-intrusive)
- Larger path volume sampling = fewer paths & less cost required
- Continuous auto-zeroing function ensures zero stability
|
| SITRANS FUS1010 (Standard) and SITRANS FUP1010 (Portable) |
| General purpose liquid flowmeters. FUS1010 are dedicated wall mount units while FUP1010 are portable units that can be used for field surveys or temporary installations. Both are used for a wide variety of applications, including water & wastewater, HVAC, power and processing. |
| |
| |
| |
| |
| |
| |
| SITRANS FUE1010 (Energy) |
| These meters are ideally suited to thermal energy/power industry applications
such as chilled & hot water sub-metering, condenser water, potable water and
glycol and brine solution, thermal storage. |
| |
| |
| SITRANS FUH1010 (Oil) |
| These flowmeters are ideal for applications carrying crude oil, refined
petroleum or liquefied gas. There are meters for two application areas:
viscosity compensated volumetric flowmeters and standard volume (net) mass
flowmeters. |
| |
| SITRANS FUH1010 (Interface Detection) |
| This interface detection meter is ideal for oil applications where a
differentiation between various liquids in a pipeline is needed. |
| |
| SITRANS FUG1010 (Gas) |
| These gas flowmeters suit most natural and process gas applications, including
checkmetering, allocation, flow survey verification, lost and unaccounted for
(LAUF) gas analysis, production and storage. |
| |
| |
| |
| SITRANS FUS1020 (Basic) |
| These general purpose low cost flowmeters are suitable for many clean liquid
applications in industries such as water & wastewater, chemical feed and
HVAC and power. |
| |
| |
| |
| |
| SITRANS FUP1010 Kit for the water and wastewater industry |
| The Check
Metering Kit for the water and wastewater industry with dual mode of operation
enables it to be used on a very wide range of applications. |
| |
| |
| |
| |
| |
| |
| SITRANS FUE1010 Kit for the HVAC industry |
| The Check Metering Kit for the
HVAC industry has been developed for the heating ventilation and air
conditioning industry with high precision transducers and platinum resistance
temperature detectors (RTD’s). |
 |
|
| |
| |
| SITRANS FUS060 |
The SITRANS FUS060 is a high performance, easy to mount transmitter developed for rugged industries within oil, petrochemicals, power plants or water and wastewater. It is especially suitable for applications that demand accuracy, custody transfer approvals and bus communication. |
| |
| |
| |
| |
| |
| |
| SITRANS F US SONO 3100/FUS060 |
| The SONO 3100 sensor and the FUS060 transmitter is an ideal combination for applications where process shut down is impossible during service and where there is a need for extreme high/low temperatures and pressures. The FUS060 transmitter offers Profibus PA or HART communication. Nominal sizes range from DN 100 to DN 1200 (from 4" to 48") and available pipe materials include carbon or stainless steel. |
| |
| |
| |
| SITRANS SONO 3300/FUS060 |
| The combination of sensor SONO 3300 sensor and FUS060 transmitter is ideal for
applications within the general industry where measurements are independent of
liquid temperature, density, pressure and conductivity. Nominal sizes range from
DN 50 to DN 300 (from 2" to 12") and pipe materials include carbon steel. |
| |
| |
 |
|
| |
| |
| SITRANS FUS380 |
| The SITRANS FUS380 is a battery or mains supply powered
flowmeter designed for numerous standard applications. The FUS380 can be used in
all utility applications that do not require custody transfer approvals. It has
a display that indicates various measurement values and diagnostics. The
flowmeter measures in both flow directions, has two pulse outputs and is
available from DN 50 to 1200 (from 2" to 48"). |
| |
| |
| |
SITRANS FUE380
|
| The SITRANS FUE380 is the custody transfer approved version of FUS380. The approval (MID, PTB, EN 1434 and OIML R75) is valid for heat metering systems. It is available from DN 50 to 1200 (from 2" to 48"). |
| |
| |
| |
| |
| |
| |
| SITRANS FUE950 |
| SITRANS FUE950 is a universal energy calculator, which
meets the requirements of OIML R75, EN 1434 and PTB. It is battery or mains
powered and has different outputs including pulse and M-Bus. It is designed for
use in hot water, chilled water and cooling/heating applications. If needed, the
necessary temperature sensors and pipe mounting parts can be ordered along with
the calculator. The calculator can be used with SITRANS FUS/E380 and SITRANS F M
MAG. |
 |
|
| |
| SITRANS F US SONOKIT/FUS060 |
| The mains powered SITRANS F US SONOKIT is
suitable for various high performance and pressure pipes ranging from DN 100 to
DN 4000 (from 4" to 160"). The kit includes all necessary parts and special
tools to make a complete installation of a 1-, 2- or 4-track flowmeter on an
empty pipe. Hot tap installation can be performed by means of extra tools. It is
available in an EX approved version and has analog output as well as bus
communication. Media temperature can be up to 200 ºC (392 ºF). |
| |
| |
| |
| SITRANS FUS880 |
| The SITRANS FUS880 is a battery-powered flowmeter, which
can be used for irrigation and water supply management. It is designed for pipes
ranging from DN 200 to DN 1200 (from 8" to 48") and has the option between 1 and
2 tracks. The flowmeter can be installed in low pressure pipelines made of
various materials such as plastics and concrete and is approved for underground
installation and operation. Media temperature can be up to 60 ºC (140 ºF). |
 |
|
| |
| SITRANS F US Thickness Gauge |
The easy-to-use, stand-alone digital ultrasonic pipe wall thickness gauge is an indispensable tool in accurate clamp-on ultrasonic flow measurement. Since even the smallest miscalculation of the pipe wall thickness can have a major impact on a clamp-on flowmeter's accuracy, the pipe thickness gauge has to be extremely precise. This is why the standard probe operates at a 5 MHz frequency enabling it to measure even the smallest pipe thickness. Although the thickness gauge was originally designed to increase the accuracy of clamp-on flowmeters, it can be used to measure the thickness of any pipe wall. |
 |
|
| |