- Rosemount Tank Gauging
- Cameron Measurement
- Siemens
- Leakwise
- Precision Digital
- Labkotec
- Enerac
- Contrec
- Berthold
- BWB Controls / Axelson
- Anderson Greenwood / AGCO
- ITT NeoDyn
- Graphic Controls
- Fluidwell
- Xylem McDonnell Miller
- PKP Process Instrumentation
- CS Instruments
- Noshok
- Hitrol
- Radioactive Services In Singapore
- Bopp & Reuther
- Chenzhu
- G&A
- Sensia Measurement
- Gefran
- Emerson Measurement Instrumentation
- Supmea
- Meister AFME
- Recorders
-
Tank Gauging System
-
Tank Gauging System
- Rosemount 5900C Radar Level Gauge
- Rosemount 5900S Radar Level Gauge
- Rosemount 5300 GWR Level Transmitters
- Rosemount 5400 Radar Level Transmitter (Obsolete)
- Rosemount 565/566 Multiple Spot or Average Temperature Sensor
- Rosemount 2240S Multi-input Temperature Transmitter
- Rosemount 2410 Tank Hub
- Rosemount 2230 Graphical Field Display
- Rosemount 2460 System Hub
- Rosemount 3051S Pressure Transmitter
- Rosemount 2120 Vibrating Fork Liquid Level Switch
- Rosemount 2130 High Temperature Level Switch SIL2
- SmartPower Solutions
- Tank Gauging System
- Tank Gauging System
- Tank Gauging System
-
Tank Gauging System
- RTG 3920 Horn Antenna Gauge
- RTG 3930 Parabolic Antenna Gauge
- RTG 3950 Still-pipe Array Antenna Gauge
- RTG 3960 LPG/LNG Gauge
- DAU 2100 Data Acquisition Unit
- RDU40 Remote Display Unit
- MST - Multiple Spot or Average Temperature Sensor
- WLS - Water Level Sensor
- FCU 2160 - Field Communication Unit
- FBM 2180 - Field Bus Modem
- AMS Trex Device Communicator
-
Tank Gauging System
- Radioactive Instruments
-
Temperature
-
Temperature
- Rosemount™ 3144P Temperature Transmitter
- Rosemount™ 644 Temperature Transmitter
- Rosemount™ 148 Temperature Transmitter
- Rosemount™ 248 Head Mount Temperature Transmitter
- Rosemount™ 214C RTD Temperature Sensor
- Rosemount™ 214C Thermocouple Sensor
- Rosemount™ 0085 Pipe Clamp Temperature Sensor
- Rosemount™ 114C Thermowell
- Temperature
- Temperature
-
Temperature
- SIEMENS SITRANS TH100 (4 to 20 mA, PT100) Temperature Transmitter
- SIEMENS SITRANS TH200 (4 to 20 mA, universal) Temperature Transmitter
- SIEMENS SITRANS TH300 (HART, UNIVERSAL) TEMPERATURE TRANSMITTER
- SIEMENS SITRANS SIEMENS SITRANS TH320/420 TEMPERATURE TRANSMITTER
- SIEMENS SITRANS TH100 Slim (Pt100) Temparature Transmitter
- Temperature
- Temperature
- Temperature
- Temperature
- Temperature
-
Temperature
- Noshok 100 Series Industrial Type Bimetal Thermometers
- Noshok 150 Series Testing and General Purpose Bimetal Thermometers
- Noshok 300 Series Bimetal Thermometers with External Reset and Sanitary connection
- Noshok 350 Series Testing and General Purpose Bimetal Thermometers with External Reset
- Noshok 300/400/600/700 Series Vapor Actuated Remote Dial Indicating Thermometers
- Temperature
- Temperature
- Temperature
- Temperature
- Temperature
- Temperature
- Temperature
- Temperature
-
Temperature
-
Pressure
- Pressure
- Precision Digital Pressure Gauges
-
Pressure
- Rosemount™ 2088 Gage and Absolute Pressure Transmitter
- Rosemount™ 2051 Coplanar™ Pressure Transmitter
- Rosemount™ 2051 In-Line Pressure Transmitter
- Rosemount™ 3051 Coplanar™ Pressure Transmitter
- Rosemount™ 3051 In-Line Pressure Transmitter
- Rosemount™ 3051S Coplanar™ Pressure Transmitter
- Rosemount™ 3051S In-Line Pressure Transmitter
- Rosemount 1199 Diaphragm Seal System
-
Pressure
- Noshok 640 Series Precision Heavy Duty Pressure Transducers
- Noshok 660 Series High Performance Micro-Size Transducers
- Noshok 621/622 Series Explosion-Proof Pressure Transmitters
- Noshok 623/624 Series Non-Incendive Pressure Transmitters
- Noshok 625/626 Series Intrinsically Safe Pressure Transmitters
- Noshok 628 Series Intrinsically Safe Hammer Union Pressure Transmitters
- Noshok 11 Series Sanitary Clamp Pressure Transmitters
- Noshok 25 Series Intelligent Pressure & Level Transmitter
- Noshok 800 Series Electronic Indicating Pressure Transmitter/Switch
- Noshok 30 Series “SNORKEL” Pressure & Level Transmitter
- oshok PT10 Series OEM Fixed Range Industrial Pressure Transmitters & Transducers
- Noshok PT20 Series General Purpose Fixed Range Transmitters & Transducers
- Noshok PT30 Series High Performance Fixed Range Transmitters & Transducers
- Noshok C10 / SC10 Digital Pressure Transmitter
- Noshok PT40 Series High Accuracy Fixed Range Transmitters & Transducers
- Noshok PT41 Series High Pressure Fixed Range Transmitters & Transducers
- Noshok PTI20 Series Intelligent Industrial Pressure Transmitters & Transducers
- Noshok PTI40 Series Premier Accuracy Intelligent Industrial Pressure Transmitters
- Noshok PTI30 Series High Accuracy Intelligent Industrial Pressure Transmitters & Transducers
- Pressure
-
Pressure
- 151P Low Differential Set Points (Explosion Proof)
- 152P Ultra Low System Pressure (Weather Proof)
- 160P Mid Range System Pressure (Weather Proof)
- 152P Ultra Low System pressure (Explosion Proof)
- 151P Low Differential Set Points (Explosion Proof)
- 160P Mid Range System Pressure (Explosion Proof)
- 162P High System Pressure (Explosion Proof)
- Pressure
-
Pressure
- SIEMENS SITRANS P200/210/220 FOR PRESSURE TRANSMITTER/ TRANSDUCER
- SIEMENS SITRANS P Compact FOR GAUGE AND ABSOLUTE PRESSURE
- SIEMENS SITRANS P300 for Gauge and Absolute Pressure
- SIEMENS SITRANS P320/420
- SIEMENS SITRANS P300 WITH PMC CONNECTION
- SIEMENS SITRANS LH300 Transmitter for Hydrostatic Level
- SIEMENS SITRANS LH100 TRANSMITTER FOR HYDROSTATIC LEVEL
- Pressure
-
Pressure
- 100P Internally Adjustable (Weather Proof)
- 101P Externally Adjustable (Weather Proof)
- 105P/105PP Minature Pressure Switch (Weather Proof)
- 110P Low Pressure Range (Weather Proof)
- 115P/115PP Built-To-Order (Weather Proof)
- 125P Higher Range Pneumatic Applications ( Weather Proof)
- 130P Adjustable Thru Port Cap-Pressure (Weather Proof)
- 131P Adjustable With Selectable Deadband-pressure (Weather Proof)
- 132P Pneumatic Or Low Impulse Hydrauic (Weather Proof)
- 142P Div 1&2 Hermetic-Ultra Low Range (Weather Proof)
- 200P Hydraulic Service-Internally Adjustable (Weather Proof)
- 201P Hydraulic Service-Externally Adjustable (Weather Proof)
- 225P High Pressure Hydraulic Applications (Weather Proof)
- 231P Adjustable Hydraulic Switch (Weather Proof)
- 232P High Pressure or High Impulse Hydraulic (Weather Proof)
- 100P Div 2/Terminal Strip (Explosion Proof)
- 100P Div 1 W/Terminal Strip ( Exposion Proof)
- 100P Div 1 & 2 hermetic (Explosion Proof)
- 110P Div 2 W/Terminal Strip- Low Range ( Explosion proof)
- 110P Div 1& 2 Hermetic- Low Range (Explosion proof)
- 112P ANSI Flanged Pessure Switch (Explosion Proof)
- 115P/115PP Build-To-Order Set Point (Explosion Proof)
- 122P CPI Pressure Switch (Explosion Proof)
- 123P Flush Welded Diaphragm (Explosion Proof)
- 125P higher Range Pneumatic Applications (Explosion Proof)
- 130P AdjustableThru Port Cap (Explosion Proof)
- 131PX Adjustable Selectable Deadband (Explosion Proof)
- 132P Universal Prssure Switch (Explosion Proof)
- 200P Div 1&2 Hermetic-hydraulic (Explosion Proof)
- 225P High Pressure hydraulic Applications (Explosion Proof)
- 231P Agjustable-Hydraulic (Explosion Proof)
- 232P High Pressure-Hydraulic (Explosion Proof)
-
Pressure
- 142P Ultra Low Vacuum (Explosion Proof)
- 142P Ultra LowVacuum (Weather Proof)
- 180P High System Pressure (Weather Proof)
- 181P Compact Vacuum Switch (Weather Proof)
- 182P Adjustabe Thru Port Cap (Weather Proof)
- 142P Ultra Low Vacuum (Explosion Proof)
- 181P Compact Vacuum (Explosion Proof)
- 182P Adjustable Thru Port Cap-Vacuum (Explosion Proof)
- Pressure
- Pressure
- Pressure
-
Pressure
- Noshok 100 Series ABS & Steel Case Dry Pressure Gauges
- Noshok 200 Series Low Pressure Diaphragm Dry Pressure Gauges
- Noshok 300 Series Brass Case Liquid Filled Pressure Gauges
- Noshok 400/500 Series All Stainless Steel Dry & Liquid Filled Pressure Gauges
- Noshok 402/502 Series All Stainless Steel Extreme High Pressure Gauges, Dry & Liquid Filled
- Noshok 600/700 Series Process Dry & Liquid Filled Pressure Gauges
- Noshok 800 Series Precision Test Pressure Gauges
- Noshok 900 Series ABS & Stainless Steel Liquid Filled Pressure Gauges
- Noshok 10 Series Fractional Sanitary Pressure Gauges
- Noshok 10 Series Heavy-Duty Sanitary Pressure Gauges
- NOSHOK PGE20 SERIES GENERAL PURPOSE DIGITAL GAUGE
-
Pressure
- Noshok 200 SERIES MECHANICAL COMPACT SPDT PRESSURE SWITCHES
- Noshok 100 SERIES MECHANICAL COMPACT SPST PRESSURE SWITCHES
- Noshok 300 Series Mechanical Compact SPDT with Adjustable Hysteresis
- Noshok 400 Series Heavy-Duty Mechanical Pressure Switch
- Noshok 800 Series Electronic Indicating Pressure Transmitter/Switch
- Pressure
- Pressure
- Pressure
- Pressure
- Pressure
- Pressure Monitor / Indicators
- Pressure
- Pressure
- Pressure
- Pressure
-
Pressure
- Noshok Type 5 – Compact Diaphragm Seal
- Noshok Type 12 – Heavy-Duty Inline Diaphragm Seal
- Noshok Type 20 – Flanged Diaphragm Seal
- Noshok Type 29 – Miniature Diaphragm Seal
- Noshok Type 30 / 30H – Flush Flanged Diaphragm Seal
- Noshok Type 30L – Low-Volume Flanged Diaphragm Seal
- Noshok Type 25/25H Standard & Elevated Pressure, Non-Replaceable Diaphragm Seals
-
Flow
-
Flow
- Paddle Type Flow Switch
- Paddle type flow switch with cable connection
- Paddle-bellows flow switch for liquids, with variable switching point
- Paddle-bellows flow meter and switch for liquids
- Flap Flowmeter and switch for low viscosity liquids
- Flap Flowmeter
- Paddle-bellows type flow switch with micro switch
-
Flow
- Flow Indicator with Wiper
- Rotor-type Flow Indicator
- Flow Indicator with Turbine
- Flow Indicator with Flanges
- Flow Indicator with Flap and Scale
- Ball type Flow Indicator
- Flow Indicator with Threaded Connection
- DG11 Flow Sight Glass with Flanged Connections
- Miniature Variable Area Flow meter and Switch
- Variable area flowmeter and switch with glass measuring tube
- Plastic Variable Area Flowmeter
- Float-Type Flow Meter For low flow volumes Compact construction
- Variable Area Flowmeter With Flange Connection, Insensitive To Viscosity Changes
- Piston Type Flow Switch for Low Flow Applications
- Flow
-
Flow
- Rosemount™ Differential Pressure Flowmeters
- Rosemount™ 1495 Orifice Plate
- Rosemount™ 1496 Orifice Flange Union
- Rosemount™ 485 Annubar™ Primary Element
- Rosemount™ 1595 Conditioning Orifice Plate
- Rosemount™ 405C Compact Conditioning Orifice Plate Primary Element
- Rosemount™ 1195 Integral Orifice Primary Element
- Rosemount 8800 Series Vortex Flow Meters
- Rosemount 8800 MultiVariable Flow Meters
- Rosemount 8705 Flanged Magnetic Flow Meter Sensors
- Rosemount 8750W Magnetic Flow Meters for Utility Water Applications
- Rosemount 8711 Wafer Magnetic Flow Meter Sensors
- Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters
- Emerson Micro Motion Coriolis Flowmeters
- Cameron Turbine Flow Meter
- Cameron Ultrasonic Flow Meter - Custody Grade
- Flow
-
Flow
- SIEMENS SITRANS FM MAG 5100W Flowmeter - (Phase out and replaced by FMS500 model)
- SIEMENS SITRANS FM MAG 3100 Flowmeter - (Phase out and replaced by FMS300 model)
- SIEMENS SITRANS FM MAG 1100F Flowmeter (Phase out and replaced by FMS100 model)
- SIEMENS SITRANS FM MAG 1100 Flowmeter (Phase out & replaced by FMS100 model)
- SIEMENS SITRANS FM MAG 3100P Flowmeter (Phase out & replaced by FMS400 model)
- SIEMENS SITRANS FM MAG 5000 and 6000 Transmitter (Phase out and replaced by FMT020)
- SIEMENS SITRANS FM MAG 6000 I/6000 I Ex de Electromagnetic Flowmeter (transmitter)
- SIEMENS SITRANS FM Verificator (Verificator)
- SIEMENS SITRANS FMS500 ELECTROMAGNETIC FLOW SENSOR
- SIEMENS SITRANS FMT020 ELECTROMAGNETIC FLOW TRANSMITTER
- SIEMENS SITRANS FM TRANSMAG 2 with Sensor 911/E (Industry-specific flow system)
- SIEMENS SITRANS FM MAG 8000 (Industry-specific flow system)
- SIEMENS SITRANS FM 100 (Industry-specific flow system)
- SIEMENS SITRANS Verificator (Verificator)
- SIEMENS SITRANS FMS300 ELECTROMAGNETIC FLOW SENSOR
- SIEMENS SITRANS FMS100 ELECTROMAGNETIC FLOW SENSOR
- SIEMENS SITRANS FMS400 ELECTROMAGNETIC FLOW SENSOR
- Flow
-
Flow
- SIEMENS SITRANS FCS100 CORIOLIS/DENSITY FLOWMETER (SENSOR)
- SIEMENS SITRANS FCS500 CORIOLIS/DENSITY FLOWMETER (SENSOR)
- SIEMENS SITRANS FCS600 CORIOLIS/DENSITY FLOWMETER (SENSOR)
- SIEMENS SITRANS FCS700 CORIOLIS/DENSITY FLOWMETER (SENSOR)
- SIEMENS SITRANS FCT020 CORIOLIS/DENSITY FLOWMETER (TRANSMITTER)
- SIEMENS SITRANS FCT040 CORIOLIS/DENSITY FLOWMETER (TRANSMITTER)
- SIEMENS SITRANS FC120/140 CORIOLIS/DENSITY FLOWMETER (Multiparameter Flowmeter System)
- SIEMENS SITRANS FC520/540 CORIOLIS/DENSITY FLOWMETER (Multiparameter Flowmeter System)
- SIEMENS SITRANS FC620/FC640 CORIOLIS/DENSITY FLOWMETER (Multiparameter Flowmeter System)
- SIEMENS SITRANS FC720/FC740 CORIOLIS/DENSITY FLOWMETER (Multiparameter Flowmeter System)
-
Flow
- Liquid Flow Switches
- General Purpose Liquid Flow Switches FS 251 and FS 254
- FS 4-3T General Purpose Liquid Flow Switches
- FS 4-3 General Purpose Liquid Flow Switches
- FS 6-W High Sensitivity Liquid Flow Switches
- FS 1-W High Sensitivity Liquid Flow Switches
- FS 5 General Purpose Liquid Flow Switches
- FS 6 High Sensitivity Liquid Flow Switches
- FS 7-4E General Purpose Liquid Flow Switches
- FS 7-4 Industrial Liquid Flow Switches
- FS 7-4W Industrial Liquid Flow Switches
- FS 8-W Industrial Liquid Flow Switches
- Flow
- SIEMENS SITRANS DP Flow Transmitter
- Flow
- Flow
-
Flow
- Low Water Cut off- Mechanical for Steam Boiler
- RB-122-E-Low Water Cut-Off
- RB-24E-Low Water Cut-Off
- RBT-3000 LWCO and Fuel Economizer
- RS-1-HP High Pressure Remote Sensor
- RS-1-LP Low Pressure Remote Sensor
- Series 21/221 Make-Up Water Feeders
- Series 25-A Make-Up Water Feeder
- Series 27-W Valve
- Series 47-2/247-2 Mechanical Water Feeder/LWCO
- Series 42S LWCO/Pump Controllers
- Series 47/247 Water Feeders
- Series 51/51-2 Mechanical Water Feeders/ LWCO
- Series 53/53-2 Mechanical Water Feeders/ LWCO
- Flow
- Cameron Flow Analysers
- Cameron ITT Barton Flow Meter - Positive Displacement (PD) / Rotary Piston
- Cameron Flow Meter - Differential Pressure (DP) Cone
- Cameron Flow Element - Orifice Plates & Flanges, Senior Orifice, Meter Run
- Flow
- Flow
- Flow
- Flow
- Flow
- Averaging Pitot Tube
- Flow
- Restriction Orifice
- Flow
- Flow
- Wedge Meter
- Flow
- Rota Meters
- Cavitating Venturi
- Steam Ejector
- Cameron Flow Meter - Floco PD Meter
- Cameron Coriolis Flow Meter
- Thermal Mass Transmitter
- Paddle Switches
-
Flow
- VA 500 Thermal Mass Flow Meter
- VA 520 thermal mass flow meter
- VA 550 thermal mass flow meter
- VA 570 thermal mass flow meter
- VA 521 - Compact Inline flow meter for compressed air and other gas types
- VA 525 - Compact Inline flow meter for compressed air and nitrogen
- VD 500 - Flow sensor for wet compressed air
- VU 570 - Vortex ultrasonic sensor for flow measurement
- VX 570 - Vortex sensor for flow measurement
- M-Bus - Industrial gas meter
- PI 500 - Portable Flow Meters
- DS 400 - Flow measurement for compressed air and gases
- VA 409 Flow direction switch for compressed air systems
- DS 500 - Intelligent chart recorder for compressed air and gases
- VD 520 - Inline Differential Pressure Flow Sensor
- Flow
- Bopp and Reuther coriolis flow meter
- Flow
- Flow
- Flow
-
Flow
- E018 Explosion proof-Flow rate/totalizer with HART Communication
- E110 Flow rate indicator / totalizer with analog and pulse signal outputs
- E112 Flow rate indicator / totalizer with linearization, analog and pulse outputs
- E115 Explosion-Proof Bi-directional Flow rate Indicator / Totalizer
- E119 Explosion proof - Totalizer with receipt printer driver
- E126-EL Explosion proof - Flow Computer for liquids
- E126-EG Explosion proof - Multi-Purpose Indicator
-
Flow
- D010 DIN Panel mount - Flow rate Indicator
- D011 DIN Panel mount - Totalizer with resettable total & non-resettable accumulated total
- D012 DIN Panel mount - Flow rate Indicator / Totalizer displays flow rate & total simultaneously
- D016 DIN Panel mount - Flow rate Indicator / Totalizer with linearization and pulse signal output
- D013 DIN Panel mount - Flow rate Monitor / Totalizer with high / low alarm output
- D014 DIN Panel mount - Flow rate Indicator / Totalizer with pulse signal output
-
Flow
- F010 SA / IS - Flow rate Indicator with very large digits
- F011 SA / IS - Totalizer w/ resettable total & non-resettable acc. total
- F012 SA / IS - Flow rate Indicator / Totalizer displays flow rate and total simultaneously
- F013 SA / IS - Flow rate Monitor / Totalizer w/ one high/low alarm output
- F014 SA / IS - Flow rate Indicator / Totalizer with pulse output
- F016 SA / IS - Flow rate Indicator / Totalizer with linearization and pulse output
- F018 SA / IS - FR Indicator / Totalizer w/ linearization, pulse/alarm & analog outputs & HART Comm
- F103 WP - Flow Logger / Totalizer with linearization, analog and pulse outputs
- F110 SA / IS - FR Indicator / Totalizer, analog and pulse outputs with Modbus comm
- F111 SA / IS - Dual input Flow rate Indicator / Totalizer with two pulse outputs
- F112 SA / IS - Flow rate Indicator / Totalizer with linearization, Modbus, analog and pulse outputs
- F113 SA / IS - Flow rate Indicator / Totalizer with with high / low alarms, analog and pulse outputs
- F114 SA / IS - Ratio Monitor / Totalizer with high / low alarms and analog outputs
- F115 SA / IS - Bi-directional FR Indicator / Totalizer w/ analog, pulse signal & flow direction output
- F116 SA / IS - Differential / Sum Flow Computer w/ Modbus Comm, analog & pulse outputs
- F118 SA / IS - FR Monitor / Totalizer w/ linearization, high / low alarms, analog & pulse outputs
- F119 - FR Indicator / Totalizer w/ receipt printer driver linearization, analog & pulse outputs
- F126-EL SA / IS - Flow Computer for liquid with temperature compensation for corrected volume
- F126-EG SA / IS - Flow Computer for gas with temp. & pressure compensation for corrected vol.
- F127 SA / IS - Differential Flow Computer for liq. w/ temp. compensation for corrected vol.
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Flow
- Supmea Coriolis Mass Flowmeter
- Flow
- Oval Wheel Meter
-
Flow
-
Level
- Labkotec WBS 3000 Water Bottom Level Sensors
- LabkoNet Tank Inventory Management System
-
Level
- Rosemount™ 2051L Level Transmitter
- Rosemount™ 3051L Level Transmitter
- Rosemount™ 3051S MultiVariable™ Transmitter
- Rosemount™ 3051SAL Level Transmitter
- Rosemount™ 3051SAM Scalable ERS Measurement Transmitter
- Rosemount™ 3051S Electronic Remote Sensor (ERS)™ System
- Rosemount™ 3300 Level Transmitter - Guided Wave Radar
- Rosemount™ 5300 Level Transmitter - Guided Wave Radar
- Rosemount™ 3308 Wireless Level Transmitter - Guided Wave Radar
- Rosemount™ 3408 Level Transmitter - Non-Contacting Radar
- Rosemount™ 5408 Level Transmitter - Non-Contacting Radar
- Rosemount™ 2120 Level Switch - Vibrating Fork
- Rosemount™ 2130 Level Switch - Vibrating Fork
- Rosemount™ 2140 Level Detector - Vibrating Fork
- Rosemount™ 2160 Wireless Level Detector - Vibrating Fork
- Level
-
Level
- SIEMENS SITRANS LR100 RADAR LEVEL TRANSMITTER
- SIEMENS SITRANS LR110 RADAR LEVEL TRANSMITTER
- SIEMENS SITRANS LR120 RADAR LEVEL TRANSMITTER
- SIEMENS SITRANS LR140 RADAR LEVEL TRANSMITTER
- SIEMENS SITRANS LR150 RADAR LEVEL TRANSMITTER
- SIEMENS SITRANS LR510 RADAR LEVEL TRANSMITTER
- SIEMENS SITRANS LR530 RADAR LEVEL TRANSMITTER
- SIEMENS SITRANS LR550 RADAR LEVEL TRANSMITTER
- SIEMENS SITRANS LR580 RADAR LEVEL TRANSMITTER
- Level
- Level
- Level
- Level
- Radar
- Float Switches
- Capacitance
- Displacer
- Float Transmitters
- Capacitance Switches
- Capacitance Transmitters
- Radio Frequency
- Vibration Switches
- Electrode Switches
- Paddle Switches
- Tilt Switches
- Tank Level
- Level
- Level
- Level
- Level
-
Level
- F070 Safe area / Intrinsically safe - Level Indicator with very large digits
- F073 Safe area / Intrinsically safe - Level Monitor with one high / low alarm output
- F074 Safe area / Intrinsically safe - Level / Pump Controller with one control output
- F077 Safe area / Intrinsically safe - Level Monitor with linearization & one high / low alarm output
- F170 Safe area / Intrinsically safe - Level Monitor with with high / low alarms and analog outputs
- F173 Safe area / Intrinsically safe - Level Monitor with linearization, high / low alarms and analog outputs
- Level
- Level
- Continuous Level Measurement
- Multiphase / Interface Measurement
- Level Switch Measurement
- Mould Level Measurement
- Level
-
Level
- Displacer Type — HM-30 & 90 Series
- Electrode Type — HE-Series
- Float Type — HR-66 Series
- Capacitance Type — HCC/HPC-95R Series
- Capacitance Type — HCC/HPC-95P Series
- Capacitance Type — HCC-95T Series
- Electrode Type — HE-1S Series
- Float Type — HR-95 Series
- Float Type — HQM-77 Series
- Float Type — HR-50 Series
- Float Type — HM-90S Series
- Float Type — HM-12(10) Series
- Float Type — CS-1000
- Magnetic Float Type — HR-10 Series
- Magnetic Float Type — HR-10L Serie
- Paddle Type — HLV-Series
- Magnetic Float Type — HR-30 Series
- Pressure — HP-1A
- Thermal Mass Type — HTML-S Series
- Radio Frequency Type — HPC-96RF Series
-
Level
- Capacitance Type — HT/HPC-100CT Series
- Float Type — HT-100F Series
- Magnetic Float — HT-100R Series
- Magnetostrictive Type — HT-100M Series
- Pressure Type — HT-100P Series
- Thermal Mass Type — HTML-TM Series
- Ultrasonic Type — HUL/HUT-2000S Series
- Capacitance Type — HT/HPC-100CT-2 Series
- Thermal Mass Type — HTML-TC Series
- Ultrasonic Type — HUL/HUT-2000T&S Series
- Ultrasonic Type — HUL-2000N Series
- Level
- Level
- Level
- Level
-
Level
- SET-1000 Control unit
- SET-2000 Control unit
- Lokaset 20 Cesspool alarm
- SET/OELO2 Sensor (Leak Detection)
- SET/OSK2 Sensor (Oil-on-water Detection)
- SET/OS2 Sensor (Oil/Water Interface Detection)
- SET/TSHS2 Sensor (For Viscous Liquids)
- SET/TSH2 Sensor (For Non-Viscous Liquids)
- SET/TSSH2 Sensor (For High Temperature Non-Viscous Liquids)
- SET/TSSHS2 Sensor (For High Temperature Viscous Liquids)
- Level
- Oil-On-Water Analyser/Leak Detection
-
Panel / Process Meters
- Batch Controllers / Loading Computer
- Panel / Process Meters
- Cameron Flow Rate / Totalisers
- Flow Rate / Totalisers
- Cameron Flow Computers
- Precision Digital Indicators
- Panel / Process Meters
- Panel / Process Meters
- Precision Digital Flow rate/Totalizer
- Panel / Process Meters
- Panel / Process Meters
- Digital Panel Meters
- Panel / Process Meters
-
Panel / Process Meters
- PD6100 ProVu Strain Gauge, Load Cell & mV Digital Panel Meter
- PD6200 ProVu Analog Input Flow Rate/Totalizer
- PD6262 ProVu Dual Analog Input Flow Rate/Totalizer
- PD6300 ProVu Pulse Input Flow Rate/Totalizer
- PD6363 ProVu Dual Pulse Input Flow Rate/Totalizer
- PD6000 ProVu Process Meter
- PD6001 - ProVu Feet & Inches Level Meter
- PD6400 ProVu True RMS High Voltage & Current Digital Panel Meter
-
Panel / Process Meters
- PD6600 Loop Leader Loop-Powered Process Meter
- PD6600 Loop Leader Loop-Powered Intrinsically Safe & Nonincendive Process Meter
- PD6620 Loop Leader Loop-Powered Rate/Totalizer
- PD6620 Loop Leader Loop-Powered Intrinsically Safe & Nonincendive Rate/Totalizer
- PD685 Intrinsically Safe Type 4X, IP67 Loop-Powered Meter
- PD662 Survivor NEMA 4X Loop-Powered Process Meter
- Sabre Series
- Panel / Process Meters
-
Inst Valves - Manifolds
- Inst Valves - Manifolds
- Inst Valves - Manifolds
-
Inst Valves - Manifolds
- Noshok 100 Series – Mini Needle Valve (Hard Seat)
- Noshok 150 Series – Mini Needle Valve (Soft Tip)
- Noshok 200 Series – Multiport Needle Valve (Hard Seat)
- Noshok 300 Series – Multiport Needle Valve (Soft Seat)
- Noshok 400 Series – Standard Needle Valve (Hard Seat)
- Noshok 500 Series – Standard Needle Valve (Soft Seat)
- Noshok 600 Series – Block & Bleed Needle Valve (Hard Seat)
- Noshok 700 Series – Block & Bleed Needle Valve (Soft Seat)
- Noshok 800/850 Series – Bleed Valve (Hard Seat & Soft Tip)
- Noshok 2070 Series – 2-Valve Block & Bleed Needle Valve (Hard Seat)
- Noshok 2170 Series – 2-Valve Block & Bleed Needle Valve (Soft Seat)
- Noshok 3070 Series – 3-Valve Double Block & Bleed Needle Valve (Hard Seat)
- Inst Valves - Manifolds
- Inst Valves - Manifolds
- Liquid Level Manifold
- Inst Valves - Manifolds
- Inst Valves - Manifolds
- Inst Valves - Manifolds
-
Inst Valves - Manifolds
- Noshok 2000 / 2100 Series – 2-Valve Static Pressure Block & Bleed
- Noshok 2020 / 2120 Series – 2-Valve Liquid Level Manifold
- Noshok 200002/210002 & 200402/210402 Series – 2-Valve Narrow Block & Bleed Manifolds
- Noshok 2530 Series – 2-Valve Natural Gas Manifold (Large Bore)
- Noshok 2602 / 2702 Series – 2-Valve Mini Block & Bleed Manifolds
- Noshok 2603/2703 & 2604/2704 Series – 2-Valve Block & Bleed Manifolds (0.156
- Noshok 2180 Series – Chart Recorder Manifold Valve
- Inst Valves - Manifolds
-
Inst Valves - Manifolds
- Noshok 3010 / 3110 Series – 3-Valve Differential Pressure Manifold (Hard & Soft Seat)
- Noshok 3040 Series – Compact 3-Valve Differential Manifold (Hard Seat)
- Noshok 3510 Series – 3-Valve Differential Manifold (Soft Seat, 0.375” Orifice)
- Noshok 3610 / 3710 Series – Mini 3-Valve Differential Manifold (Hard Seat & Soft Tip, 0.141
- Inst Valves - Manifolds
- Truck Register
-
Enclosures and Accessories
-
Enclosures and Accessories
- CONTREC S1200BATL - Lithium Batteries
- CONTREC IP67 Enclosure - Aluminium Enclosure
- CONTREC IP66 Weatherproof Enclosure - Field Mounting Enclosure
- CONTREC IP65 Stainless Steel (Custom)
- CONTREC PR-00 Thermal Panel Printer
- CONTREC PR-01 Panel Mount Impact
- CONTREC PR-02 Desktop 24VDC or 240VAC – 42 Col. Slip Printer
- CONTREC PR-03 Desktop 240VAC 80 Col. – Continuous Paper Printer
- CONTREC PR-04 Thermal Ticket Printer
-
Enclosures and Accessories
- Density
- Concentration & Bulk Flow Measurement
- Digital Panel Meters
- Process Controlling & Protection
- Valve Positioners
-
Analysers
- Gas Detectors
-
Analysers
- Rosemount™ 56 Dual Channel Transmitter
- Rosemount™ 1056 Intelligent Four-Wire Transmitter
- Rosemount™ 1066 Single Channel Transmitter
- Rosemount™ 5081 Explosion-proof Transmitter
- Rosemount™ 3900 General Purpose pH/ORP Sensor
- Rosemount™ 389 General Purpose pH/ORP Sensor
- Rosemount™ 400 Contacting Conductivity Sensor
- Rosemount™ 228 Toroidal Conductivity Sensor
- Rosemount™ 499ACL Chlorine Sensor
- Rosemount™ 499ADO Dissolved Oxygen Sensor
- Rosemount™ 499ATrDO Trace Dissolved Oxygen Sensor
- Rosemount™ T56 Clarity™ II Turbidimeter
- Rosemount™ T1056 Clarity™ II Turbidimeter
- Rosemount™ 396 pH/ORP Sensor
- Analysers
- Cameron Nuflo Water Cut Analyser
-
Analysers
- MDA-U2-PH pH ORP Meter
- MDA-PH pH ORP Meter
- MDC-P2 Dual Channel Universal Controller
- MDC-P1 Single Channel Universal Controller
- SUP-PH5019 Plastic pH Sensor
- SUP-PH5022 Germany Glass pH Sensor
- SUP-PH5014 Hydrofluoric Acid pH Sensor
- SUP-PH5013A PTFE pH Sensor for Corrosive Medium
- Standard pH Calibration Solutions
- pH Installation Accessories
- SUP-PH5018 Glass pH Sensor
- SUP-PH-5015 Glass pH Sensor
- Analysers
- Supmea Oxygen Sensor and Meter
- Analysers
- Analysers
- Analysers
- Analysers
- Signal Generators & Calibrators
- 4-20mA Set-Point Generator
-
Large Display Field Mount Indicators
-
Large Display Field Mount Indicators
- PD2-6000 Helios Process Meter
- PD2-6080 Helios Modbus Scanner with Dual Analog Inputs
- PD2-6001 Helios Feet & Inches Level Meter
- PD2-6081 Helios Feet & Inches Modbus Scanner with Dual Analog Inputs
- PD2-6060 Helios Dual Analog Input Process Meter
- PD2-6100 Helios Strain Gauge, Load Cell & mV Meter
- PD2-6200 Helios Analog Input Flow Rate/Totalizer
- PD2-6210 Helios Analog Input Batch Controller
- PD2-6262 Helios Dual Analog Input Flow Rate/Totalizer
- PD2-6300 Helios Pulse Input Flow Rate/Totalizer
- PD2-6310 Helios Pulse Input Batch Controller
- PD2-6363 Helios Dual Pulse Input Flow Rate/Totalizer
- PD2-6400 Helios High Voltage & Current Meter
- PD2-7000 Helios Temperature Meter
- PD4-6600 Loop Leader+ Large Display Loop-Powered Process Meter
- PD4-6600 Loop Leader+ Large Display Loop-Powered Intrinsically Safe Process Meter
- PD4-6620 Loop Leader+ Large Display Loop-Powered Flow Rate/Totalizer
- PD4-6620 Loop Leader+ Large Display Loop-Powered Intrinsically Safe Flow Rate/Totalizer
-
Large Display Field Mount Indicators
- PD6730X Vantageview NEMA 4X Modbus Scanner
- PD6928-GP VantageView+ NEMA 4X Loop-Powered Flow Rate/Totalizers
- PD6700 Vantageview NEMA 4X Loop-Powered Process & Level Meter (Obsolete)
- PD6900-GP VantageView+ NEMA 4X Loop-Powered Process/Feet & Inches Level Indicators
- PD6770 Vantageview NEMA 4X Large Display Loop-Powered Meter
- PD6938-GP VantageView+ NEMA 4X Pulse Input Flow Rate/Totalizer
- PD6730 Vantageview NEMA 4X Pulse Input Rate/Totalizer
-
Large Display Field Mount Indicators
- Control Stations
- Lithium Battery
- Dosimeter
- Calibrator
-
Flame and Gas Detector
-
Flame and Gas Detector
- Net Safety™ Millennium II Single Channel Transmitter
- Net Safety™ Millennium II Dual Channel Transmitter
- Net Safety™ Millennium II SC310 Catalytic Bead Combustible Gas Sensor
- Net Safety™ Millennium II SC311 Infrared Combustible Gas Sensors
- Net Safety™ Millennium II ST3 XChem Toxic Gas Sensor [Electrochemical]
- Rosemount™ 925 Fixed Gas Detection Transmitter
- Rosemount™ 925FGD Fixed Gas Detector
- Rosemount™ 935 Open Path Combustible Gas Detector
- Rosemount™ 936 Open Path Toxic Gas Detector
- Rosemount™ Incus Ultrasonic Gas Leak Detector
- Flame and Gas Detector
- Flame and Gas Detector
- Flame and Gas Detector
- Flame and Gas Detector
- Flame and Gas Detector
-
Flame and Gas Detector
- Btu Meter / Heat Calculator
-
DEW POINT
-
DEW POINT
- FA 510/515 - Dew Point Sensor for Refrigeration Dryers
- FA 500 - Dew point sensor with integrated display and alarm relay
- FA 515 Ex- Dew Point Sensor
- FA 505 - Dew Point Sensor for OEM Applications
- DP 500 - Portable dew point meter with integrated data logger
- FA 510/515 - Dew point sensor for adsorption dryers
- FA 550 - Dew point sensor in robust die-cast aluminum housing
- DP 510 - Portable dew point meter with third party sensor
- DP 400 mobile - Mobile Dew Point Measurement with Pressure Sensor
- DS 52 - Dew point measurement set for desiccant dryers
- DS 52 - Dew point measurement set for refrigeration dryers
- DS 400 Set - Stationary dew point measurement in compressed air systems
- DS 400 - Dew point set for monitoring of medical compressed air
- IAC 500 sensor for measuring ambient condition
- FO 510 - Industrial oil moisture sensor
-
DEW POINT
- Standard Measuring Chamber
- High-pressure measuring chamber up to 350 bar
- Measuring chamber for granulate dryers and gases
- Measuring chamber for atmospheric dew point
- Control and calibration set for dew point sensors
- Bypass measuring chamber up to 350 bar
- Stainless steel measuring chamber for compressed air up to 50 bar
-
DEW POINT
-
COMPRESSED AIR QUALITY
-
COMPRESSED AIR QUALITY
- Residual Oil Content Measurement OILCHECK according to ISO 8573 - Stationary Solutions
- Residual Oil Content Measurement OILCHECK according to ISO 8573 - Mobile Solution
- Particle Counter PC 400 - Stationary Ssolution according to ISO 8573
- Particle Counter PC 400 - Mobile Solution according to ISO 8573
-
COMPRESSED AIR QUALITY
- Power Meter
- Leak Detection
- Softwares
- Power Meter
-
PRESSURE SENSORS
-
PRESSURE SENSORS
- Digital Pressure Sensor DPS 16
- PTS 500 - for Measuring of Pressure and Temperature
- IAC 500 Sensor for Measuring Ambient Conditions
- Standard Pressure Sensor CS10 and CS16
- Differential Pressure Probe to Test Filter Performance
- Standard Pressure Sensor CS40
- Standard Pressure Sensor CS1.6 Absolute
- Standard Pressure Sensor CS100
- Standard pressure sensor CS250
- Standard pressure sensor CS400
- Precision Pressure Sensor CS -1...+15
-
PRESSURE SENSORS
-
Batch Controller
- Batch Controller
- Batch Controller
- Batch Controller
-
Batch Controller
- F030 SA / IS - Batch Controller with one control output
- F130 SA / IS - Batch Controller with two-stage control, pulse output and Modbus communication
- F131 SA / IS - Batch Controller with two-stage control, pulse output and analog output in relation to the flow rate
- F132 SA / IS - Batch Controller with with two-stage control and receipt printer driver
- F133 SA / IS - Delivery Controller / Dispenser with pump start and valve control
-
Batch Controller
- N410 DIN Panel mount Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs
- N413 DIN Panel mount - Batch Controller with receipt printer driver and numerical keypad
- N414 DIN Panel mount - Legal-for-trade Batch Controller with NTEP Certification and receipt printer driver
-
Batch Controller
- Contrec 515 – AC01 – Additive Controller for Volumetric Frequency Flowmeters
- Contrec 515 – BA01 – Batch Additive Controller
- Contrec 515 – CB01 – Frequency Input Blending Controller - Frequency Flow, DCV Control
- Contrec 515 – CB02 – Frequency Input Secure Blending Controller - DCV Control
- Contrec 515 – TA02 – Dual Channel On-Truck Additive Batch Controller
-
Batch Controller
- Contrec 114D – Frequency/Pulse Input Batch Controller
- Contrec 214D – Pulse/Frequency Input ATEX/IECEx Batch Controller
- Contrec 424 – Batch Controller
- Contrec 430D – Frequency Input, Numeric Keyboard Batch Controller
- CONTREC 515 – BF01 – Frequency Input Batch Controller, Tailored for Volumetric Flow Meters
- CONTREC 515 – BF02 – Analogue Input Batch Controller, Tailored for Volumetric Flow Meters
- CONTREC 515 – BF03 – Frequency Input Batch Controller, Tailored for Mass Flow Meters
- CONTREC 515 – BF04 – Analogue Input Batch Controller, Tailored for Mass Flow Meters
- CONTREC 515 – BS01 – Secure Access Batch Controller, Tailored for Inputs from Vol. Flow Meters
- CONTREC 515 – BS03 – Secure Dual Stage Batch Controller
- CONTREC 515 – BT01 – Secure Dual Stage Batch Controller
- CONTREC 515 – LK01 – Leak Monitor
-
Batch Controller
- CONTREC 515 – BR01 – Frequency Input Batch/Ratio Controller, Tailored for Vol. Flow Meters
- CONTREC 515 – BR02 – Analogue Input Batch/Ratio Controller for Vol. Flow Meters
- CONTREC 515 – BR03 – Frequency Input Batch/Ratio Controller, Tailored for Mass Flow Meters,
- CONTREC 515 – BR04 – Analogue Input Batch/Ratio Controller, Tailored for Mass Flow Meters
- CONTREC 515 – CR02 – Analogue Input Batch Ratio Controller
- Batch Controller
- Batch Controller
-
Multi-Purpose Indicators
- Multi-Purpose Indicators
- Multi-Purpose Indicators
-
Multi-Purpose Indicators
- F090 SA / IS - Multi-Purpose Indicator input loop powered with very large digits
- F490 SA / IS - Loop Powered, Multi-Purpose Indicator for universal applications
- F093 SA / IS - Tachometer Monitor displays engine speed and running hours with alarm output
- F190 SA / IS - Multi-Purpose Monitor with alarm outputs and configurable hysteresis
- Process Monitor
- Production and LACT Sampling
-
Flow Computers
- Flow Computers
- Flow Computers
- Flow Computers
-
Flow Computers
- CONTREC 515 – PP01 – Pressurised Petroleum Flow Computer
- CONTREC 515 – FA02 – Add/Subtract Flow Computer - 2 Channel Input (Mass) Flow Computer
- CONTREC 515 – FA03 – Add/Subtract Flow Computer - 2 Channel Input (Energy)
- CONTREC 515 – FN01 – Frequency Input Net Oil Flow Computer, Tailored for Mass Flow Meters
- CONTREC 515 – FA01 – Add/Subtract Flow Computer - 2 Channel Input (Volume)
- CONTREC 425 Flow Computer
-
Flow Computers
- CONTREC 515 – GN01 – Frequency Input Natural Gas Flow Computer
- CONTREC 515 – GN02 – Analogue Input Natural Gas Flow Computer
- CONTREC 515 – GN03 – Natural Gas Flow Computer(AGA - 8) - DP Meter (Mass Span)
- CONTREC 515 – GN04 – Natural Gas Flow Computer (AGA - 8) - DP Meter (ISO/Cone)
- CONTREC 515 – GN05 – Natural Gas Flow Computer (AGA - 8) - DP Meter (AGA - 3)
- CONTREC 515 – GN06 – Natural Gas Flow Computer (AGA - 8) - DP Meter (Volumetric Span)
- CONTREC 515 – GN11 – Natural Gas Flow Computer (SGERG) - Quadrature Input
- CONTREC 515 – GN12 – Natural Gas Flow Computer (SGERG) - Analogue Flow
- CONTREC 515 – GN13 – Natural Gas Flow Computer (SGERG) - DP Meter (Mass Span)
- CONTREC 515 – GN14 – Natural Gas Flow Computer (SGERG) - DP Meter (ISO/Cone)
- CONTREC 515 – GN16 – Natural Gas Flow Computer (SGERG) - DP Meter (Volumetric Span)
- CONTREC 515 – DG01 – Density Converter (Gas)
- CONTREC 515 – DG02 – Density Converter
- CONTREC 515 – GC01 – Ideal Gas Computer - Quadrature Input
- CONTREC 515 – GC02 – Ideal Gas Computer - Analogue Flow
- CONTREC 515 – GC03 – Ideal Gas Computer - DP Meter (Meter Span)
- CONTREC 515 – GC04 – Ideal Gas Computer - DP Meter (ISO/Cone)
- CONTREC 515 – GC06 – Ideal Gas Computer - DP Meter (Volumetric Span)
-
Flow Computers
- CONTREC 515 – HC01 – Heat Calculator - Frequency Flow (Volume)
- CONTREC 515 – HC02 – Heat Calculator - Analogue Flow (Volume)
- CONTREC 515 – HC03 – Heat Calculator - DP Meter (Mass Span)
- CONTREC 515 – HC04 – Heat Calculator for stacked DP meters (ISO 5167 and V-Cones)
- CONTREC 515 – HC06 – Heat Calculator - DP Meter (Volumetric Span)
- CONTREC 515 – HC12 – Heat Calculator - Heat Calculator - Analogue Flow (Mass)
- CONTREC 212 – Heat Calculator
-
Flow Computers
- CONTREC 515 – SC01 – Frequency Input Steam Computer
- CONTREC 515 – SC02 – Analogue Input Steam Computer
- CONTREC 515 – SC03 – Steam Flow Computer
- CONTREC 515 – SC04 – Steam Computer - DP Meter (ISO/Cone)
- CONTREC 515 – SC05 – Steam Computer - DP Meter (AGA - 3)
- CONTREC 515 – SC06 – Steam Computer - DP Meter (Volumetric)
- CONTREC 515 – CS02 – Condensate and Steam Flow Computer
- CONTREC 515 – CS12 – Condensate and Steam Flow Computer
- Flow Computers
- Flow Computers
- Blending System
- Metering System
- SAMPLING
- Turbine Flow Electronics
- Ultrasonic Flow Meters
-
JISKOOT Sampling Product - Custody Transfer and Fiscal Sampling
- JISKOOT Sampling Product - Custody Transfer and Fiscal Sampling
- JISKOOT Sampling Product - Custody Transfer and Fiscal Sampling
-
JISKOOT Sampling Product - Custody Transfer and Fiscal Sampling
- JISKOOT 210SD Severe Duty Cell Sampler
- JISKOOT 210P & 210P-HP Pneumatic Hydrocarbon Cell Sampler
- JISKOOT 210EH & 210EH-HP Hydraulic Hydrocarbon Cell Sampler
- JISKOOT 210HT High Temperature Cell Sample
- JISKOOT 210 Hybrid Cell Sampler
- JISKOOT 710EL-MC Cell Electrically Driven Flow-Through Sample Extractor
- JISKOOT SCV Sampling Check Valve
-
JISKOOT Sampling Product - Custody Transfer and Fiscal Sampling
- JISKOOT 210P & 210P-HP Pneumatic Heavy Hydrocarbon Probe Sampler
- JISKOOT 210EH & 210EH-HP Hydraulic Heavy Hydrocarbon Probe Sampler
- JISKOOT 210SD Severe Duty Sample Probe
- JISKOOT 210HT High Temperature Sample Probe
- JISKOOT 710EL-MC Probe Electrically Driven In-Line Sample Extractor
- JISKOOT SCV Sampling Check Valve Liquid Probe
- JISKOOT Probe Sampler Weatherproof Housing
- JISKOOT Hydraulic Sample Probe Extractor
- JISKOOT Sampling Product - Custody Transfer and Fiscal Sampling
- JISKOOT Sampling Product - Custody Transfer and Fiscal Sampling
- JISKOOT Sampling Product - Custody Transfer and Fiscal Sampling
- Metering Supervisory and Uncertainty
- Process Safety
- Communication
- Supplementary Components
- Digitalization
-
WEIGHT MEASUREMENT
- WEIGHT MEASUREMENT
- WEIGHT MEASUREMENT
- WEIGHT MEASUREMENT
- WEIGHT MEASUREMENT
- WEIGHT MEASUREMENT
- WEIGHT MEASUREMENT
- WEIGHT MEASUREMENT
- WEIGHT MEASUREMENT
- WEIGHT MEASUREMENT
-
WEIGHT MEASUREMENT
- SIEMENS Belt Scale Milltronics MLC
- SIEMENS Belt Scale Milltronics MUS
- SIEMENS Belt Scale Milltronics MCS
- SIEMENS Belt Scale Milltronics MSI and MMI
- SIEMENS Belt Scale Milltronics WD600
- SIEMENS Speed Sensor Milltronics TASS
- SIEMENS SPEED SENSOR MILLTRONICS RBSS
- SIEMENS SPEED SENSOR SITRANS WS300
- SIEMENS Accesories Calibration Weight Lifter Milltronics MWL
- SIEMENS Accesories Test Chain
- SIEMENS Accesories Test Chain Storage Reel
- SIEMENS Accesories Bend Pulleys
- Load Cells
- Radiation Protection
- Light & Horn Series
- Loop Powered Meters
-
Explosion-Proof
-
Explosion-Proof
- PD6938-EX ProtEX+ Pulse Input Explosion-Proof Flow Rate/Totalizer
- PD6938-HA ProtEX+ Pulse Input Explosion-Proof & Intrinsically Safe Flow Rate/Totalizer
- PD6938-IS ProtEX+ Pulse Input Intrinsically Safe Flow Rate/Totalizer
- PD6830 ProtEX-RTP Explosion-Proof Pulse Input Flow Rate/Totalizer
- PD8-6300 ProtEX-MAX Explosion-Proof Pulse Input Flow Rate/Totalizer
- PD8-6100 ProtEX-MAX Explosion-Proof Strain Gauge, Load Cell & mV Meter
- PD8-6200 ProtEX-MAX Explosion-Proof Analog Input Flow Rate/Totalizer
- PD8-6363 ProtEX-MAX Explosion-Proof Dual Pulse Input Flow Rate/Totalizer
- PD8-6262 ProtEX-MAX Explosion-Proof Dual Analog Input Flow Rate/Totalizer
- Explosion-Proof
-
Explosion-Proof
- PD6900-HA ProtEX+ Explosion-Proof & I.S. Loop-Powered Indicators
- PD6928-HA ProtEX+ Explosion-Proof & I.S. Loop-Powered Rate/Totalizers
- PD663 ProtEX-Lite Explosion-Proof Loop-Powered Meter
- PD6870 ProtEX-FarVu Explosion-Proof Large Display Loop-Powered Meter
- PD6800 ProtEx-Pro Explosion-Proof Loop-Powered Process & Level Meter (Obsolete)
- Explosion-Proof
- Explosion-Proof
- Explosion-Proof
-
Explosion-Proof
- Light and Horn Series
- Multi-Channel Controllers
- Field Mounted Indicators
- Surge Protective Device
- Signal Isolator
- Safety Relay
- Smart IO
- Others
- Surge Protection Device
-
Oil, Grease and Sand Separators Alarm Devices
-
Oil, Grease and Sand Separators Alarm Devices
- idSET-OTM Oil Separator Alarm System (Controller and Sensor)
- OMS-1 Oil Separator Alarm (Controller and Sensor)
- idSET-34 Oil Separator Alarm (Controller) and idOil Sensors
- idOil-30 Oil Separator Alarm (Controller) and idOil Sensors
- idOil-D30 Oil Separator Alarm (Controller) and idOil Sensors
- idOil-Solar Oil Separator Alarm (Controller) and idOil Sensors
- idOil-30 (3G) Oil Separator Alarm (Controller) and idOil Sensors
- idOil-30 Battery (3G) Separator Alarm (Controller) and idOil Sensors
- Battery Box 10
- Oil, Grease and Sand Separators Alarm Devices
-
Oil, Grease and Sand Separators Alarm Devices
- Data Communication
-
Flow and Volume Measuring Instruments
- Flow and Volume Measuring Instruments
- Flow and Volume Measuring Instruments
- Flow and Volume Measuring Instruments
- Flow and Volume Measuring Instruments
- Flow and Volume Measuring Instruments
- Flow and Volume Measuring Instruments
- Flow and Volume Measuring Instruments
- Flow and Volume Measuring Instruments
- Flow and Volume Measuring Instruments
- Flow and Volume Measuring Instruments
- Flow and Volume Measuring Instruments
- Flow and Volume Measuring Instruments
-
Density and Concentration Meter
- Density and Concentration Meter
-
Density and Concentration Meter
- Bopp & Reuther Density and Concentration Meter Series DIMF 2.0 TVS
- Bopp & Reuther Density and Concentration Meter Series DIMF 2.0 PV
- Bopp & Reuther Density and Concentration Meter Series DIMF 2.0 PVS with Universal Computer UR06 / ERW 700
- Bopp & Reuther Density and Concentration Meter Series DIMF 2.0 TWS
- Density and Concentration Meter
- Density and Concentration Meter
- Density and Concentration Meter
- Universal Flow Computer for Liquids
- Dosing Solutions
Rosemount™ Level Measurement
Our extensive selection of level transmitters, detectors, switches, and accessories for measuring liquids and solids is designed to enhance process optimization and safety at your facility, catering to both the most demanding applications involving viscous, corrosive, and aggressive media as well as simpler tasks.
Gain ease-of-use, reliability and accuracy with Emerson's Rosemount level measurement sensors and technologies.
Featured Video 
Introducing the Rosemount 3408 Non-Contacting Radar Level Transmitter
The Rosemount 2051L Level Transmitter ensures dependable performance, offering level measurements across various process connections, materials, and output protocols. It is safety certified and supports Tuned-System™ Level assembly with direct mounting capabilities. Designed with a Local Operator Interface (LOI), this device facilitates straightforward on-site commissioning.
|
Specifications
|
|
|
|
Up to 300 psi (20,68 bar) |
| Process Temperature Range | Based on fill fluid - Maximum 401°F (205°C), Minimum -157°F (-105°C) |
| Communication Protocol | 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS®, 1-5 V Low Power HART® |
| Seal System Type | Direct Mount, Tuned-System |
| Transmitter Connection | Welded-Repairable |
| Process Connection | Flanged: ANSI/ASME, EN/DIN, JIS |
| Process Wetted Material | 316L SST, Alloy C-276, Tantalum |
| Diagnostics | Basic Diagnostics |
| Certifications/Approvals | SIL 2/3 certified to IEC 61508 by an independent 3rd party, NACE®, hazardous location, see full specs for complete list of certifications |
Features
- Designed with a variety of process connections, materials and output protocols to meet diverse application requirements
- Tuned-System Level assembly and direct mounting produce optimal performance for level applications
- SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
- Local Operator Interface (LOI) for simple, local commissioning on-site without the use of extra tools or training
- Optimized seal system construction ensures a quality measurement in harsh process conditions
Direct mount or use a Tuned-System™ assembly that optimizes performance and reduces temperature effects by 10-20% for improved response time by over 80% versus traditional installations. Built-in diagnostics detect electrical loop issues and alert you to corrosion, water in the housing, or unstable power supply. Available with a graphical, back-lit display, Bluetooth® connectivity, Level specific configuration and enhanced software capabilities designed to access the data you need faster than ever before.
Product Datasheet:Rosemount™ 3051L Level Transmitter
Manual:Rosemount™ 3051L Level Transmitter
|
Specifications
|
|
|
|
Up to 5-year limited warranty |
| Max. Operating Pressure | Up to 300 psi (20,68 bar) |
| Process Temperature Range | Based on fill fluid: |
| Maximum 401°F (205°C), Minimum -157°F (-105°C) | |
| Communication Protocol | 4-20 MA HART®, WirelessHART®, FOUNDATION™ fieldbus, PROFIBUS® PA, 1-5 V Low Power HART® |
| Seal System Type | Direct Mount, Tuned-System |
| Transmitter Connection | Welded-Repairable |
| Process Connection | Flanged: ANSI/ASME, EN/DIN, JIS |
| Process Wetted Material | 316L SST, Alloy C-276, Tantalum |
| Diagnostics | Basic Diagnostics, Process Alerts, Loop Integrity Diagnostics, Plugged Impulse Line Diagnostics |
| Certifications/Approvals | SIL 2/3 certified to IEC 61508 by an independent 3rd party, NACE®, hazardous location, see full specs for complete list of certifications |
| Wireless Update Rate | 1 sec. to 60 min., user selectable |
| Power Module Life | Up to 10-year life, field replaceable (order separately) |
| Wireless Range | Internal antenna (225 m) |
Features
- Tuned-System Level assembly and direct mounting produce optimal performance for level applications
- Application specific configuration allows you to transform your pressure transmitter into a level transmitter with volume calculations
- Complete level assemblies are leak-tested and calibrated to reduce leak points up to 70% and simplify installation
- 10-year installed stability and 150:1 rangedown produce reliable measurements and wide application flexibility
- Bluetooth® wireless connectivity unlocks a far simpler process to perform maintenance and service tasks without the need for a physical connection or separate configuration tool
- The graphical, back-lit display allows for easy operation in 8 different languages in all lighting conditions
- Loop Integrity and Plugged Impulse Line diagnostics detect electrical loop issues and plugged impulse piping before it impacts the quality of the process for increased safety and reduced downtime
- Quick service buttons offer built-in configuration buttons for streamlined commissioning
- SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
The Rosemount 3051S MultiVariable Transmitter is an exceptional solution designed to measure combinations of differential pressure, static pressure, and process temperature. This multivariable transmitter is a cost-effective option that minimizes the need for pipe penetrations, impulse piping, and connection systems. Additionally, it features built-in flow calculations for fully compensated mass flow measurements.
|
Specifications
|
|
|
|
Up to 15-year limited warranty
|
|
|
Up to 200:1 |
| Communication Protocol | 4-20 mA HART™, WirelessHART®, FOUNDATION™ Fieldbus |
| Measurement Range | Up to 2000 psi (138 bar) differential, Up to 6092 psi (420 bar) static |
| Process Wetted Material | 316L SST, Alloy C-276, Tantalum, Gold-plated 316L SST |
| Diagnostics | Basic Diagnostics |
| Certifications/Approvals | NSF, NACE™, hazardous location, see full specs for complete list of certifications |
Features
- Measures multiple variables and standardizes on a single model number for streamline process and cost-efficiency
- Reduces costs by eliminating the need for stacked transmitters and additional wiring
- Primary elements available as assemble-to options for simple installation and commissioning
- Multivariable design reduces pipe penetrations, impulse piping and connection systems for cost-savings
- Callendar-Van Dusen sensor matching improves temperature accuracy enabling best-in-class flow calculations
- All-welded, SuperModule™ design offers industry-leading accuracy in harsh environments and applications
- Engineering Assistant Software allows for configuration in two easy steps
- Ultra for Flow provides optimized flow readings with a ±0.04% of reading accuracy
- Designed with built-in flow calculations for direct reporting of fully-compensated mass, energy or volumentric flow
The Rosemount 3051SAL Level Transmitter enables accurate pressure measurements in extreme conditions, providing superior capabilities for both pressurized and vented tank level measurements. This safety-certified transmitter is equipped with advanced diagnostics for enhanced insight. It is designed for direct and remote mounting, balanced systems, and Tuned-System™ assemblies, making it adaptable to various demands and process requirements for level applications.
|
Specifications
|
|
|
|
Up to 10,000psi (689.48 bar) |
| Process Temperature Range | Based on fill fluid - Maximum 770°F (410°C), Minimum -157°F (-105°C) |
| Communication Protocol | 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus |
| Seal System Type | Direct Mount, Remote Mount, Tuned-System, Balanced System |
| Transmitter Connection | Welded-Repairable, All Welded |
| Process Connection | Flanged: ANSI/ASME, EN/DIN, GOST, & JIS |
| Threaded: NPT, DIN, ISO | |
| Hygienic | |
| Process Wetted Material | 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L SST, see full specs for complete list of materials |
| Diagnostics | Basic Diagnostics, Loop Integrity, Process Intelligence, Plugged Impulse Line |
| Certifications/Approvals | SIL 2/3 certified to IEC 61508 by an independent 3rd party, NACE®, 3A, hazardous location, see full specs for complete list of certifications |
Features
- Allows for direct mounting, remote mounting and balanced and tuned-systems to meet various application requirements
- Tuned-Systems can reduce temperature effects by 10-20% and improve response time by 80% vs. traditional installations
- Offers a variety of process connections including flanged, threaded and hygienic seals for application flexibility
- Welded-repairable construction allows the seal system to be repaired and all welded design provides a robust connection for challenging applications
- Scaled variable allows transmitter to output level units
- Remote display offers direct mount process connections with access to transmitter interface at grade
- SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
- Advanced diagnostics offer diagnostic coverage to detect electrical loop issues and abnormal process conditions
The Rosemount 3051SAM Transmitter for ERS applications is available in both Coplanar and in-line styles and is part of the Rosemount 3051S Electronic Remote Sensor (ERS)™ System. This system utilizes a digital architecture to calculate differential pressure through two pressure sensors connected by an electrical cable. The sensors in the 3051S ERS System can be any combination of the 3051SAM and 3051SAL models. The 3051SAM provides various process connections, including threaded NPT, flanges, manifolds, and Rosemount 1199 Remote Seals.
|
Specifications
|
|
|
|
Up to 10,000psi (689.48 bar) |
| Process Temperature Range | Based on fill fluid - Maximum 770°F (410°C), Minimum -157°F (-105°C) |
| Communication Protocol | 4-20 mA HART® |
| Transmitter Connection | Welded-Repairable, All Welded |
| Process Connection | Flanged: ANSI/ASME, EN/DIN, GOST, & JIS Threaded: NPT, DIN, ISO Hygienic |
| Process Wetted Material | 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L SST, see full specs for complete list of materials |
| Diagnostics | Basic Diagnostics |
| Certifications/Approvals | SIL 2/3 certified to IEC 61508 by an independent 3rd party, 3A, NSF, NACE®, hazardous location, see full specs for complete list of certifications |
Features
- Provides DP Level measurements with a faster response time than traditional systems
- Sensors are independently installed without heat tracing and insulation to offer simple installation
- Entire system utilizes a single 2-wire, 4-20 mA HART® loop for straightforward system integration
- Digital architecture delivers stable measurement for applications with excessive temperature variation
- Each sensor can be independently serviced for simplified maintenance
- Graphical interface of device dashboard offers simple configuration, commissioning and troubleshooting
- Additional monitoring information of static pressure and sensor module temperature provide improved process insights
- SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
Featuring best-in-class performance and measurement stability, the Rosemount 3051S Electronic Remote Sensor (ERS)™ System is engineered with flexible, digital architecture. The ERS System calculates differential pressure electronically using two pressure sensors linked together with an electrical cable. Easy to install, this safety-certified system is engineered for faster response time than traditional systems, providing you with exceptional performance in a wide range applications.
|
Specifications
|
|
|
|
Up to 10,000psi (689.48 bar) |
| Process Temperature Range | Based on fill fluid - Maximum 770°F (410°C), Minimum -157°F (-105°C) |
| Communication Protocol | 4-20 mA HART® |
| Seal System Type | Direct Mount |
| Transmitter Connection | Welded-Repairable, All Welded |
| Process Connection | Flanged: ANSI/ASME, EN/DIN, GOST, & JIS |
| Threaded: NPT, DIN, ISO | |
| Hygienic | |
| Process Wetted Material | 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L SST, see full specs for complete list of materials |
| Diagnostics | Basic Diagnostics |
| Certifications/Approvals | SIL 2/3 certified to IEC 61508 by an independent 3rd party, 3A, NSF, NACE®, hazardous location, see full specs for complete list of certifications |
Features
- Provides DP Level measurements with a faster response time than traditional systems
- Sensors are independently installed without heat tracing and insulation to offer simple installation
- Digital architecture delivers stable measurement for applications with excessive temperature variation
- Each sensor can be independently serviced for simplified maintenance
- Entire system utilizes a single 2-wire, 4-20 mA HART® loop for straightforward system integration
- Graphical interface of device dashboard offers simple configuration, commissioning and troubleshooting
- Additional monitoring information of static pressure and sensor module temperature provide improved process insights
- SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
The Rosemount 3300 Level Transmitter offers a dependable and cost-effective solution for liquid applications in level and interface measurements. It features no moving parts, requires no calibration, and is largely unaffected by process conditions. With top-down level and interface measurements, you maintain complete control over your level monitoring.
|
Specifications
|
|
|
|
Full vacuum to 580 psi (Full vacuum to 40 bar) |
| Operating Temperature | -40 to 302°F (-40 to 150°C) |
| Communication Protocol | 4-20 mA/HART™, Modbus® |
| Probe Types | Rigid single lead, Segmented single lead, Flexible single lead, Flexible twin lead, Coaxial, PTFE coated probes |
Features
- The Rosemount 3300 can be equipped with a wide range of probes to fit most applications
The Rosemount 5300 Level Transmitter is ideal for challenging measurements on liquids, slurries, and solids, offering state of the art reliability and safety features in level and interface applications. Rosemount 5300 offers several advantages such as easy installation, no need for calibration, and is unaffected by process conditions. Also, it is SIL 2 certified making it your first choice for safety applications. It has a robust construction and features powerful built-in diagnostics allowing you to focus on the essential part - your plant.
|
Specifications
|
|
|
|
± 0.12 in. (3 mm) |
| Repeatability | ± 0.04 in. (1 mm) |
| Measurement Range | Up to 164 ft (50 m) |
| Operating Pressure | Full vacuum to 5000 psi (Full vacuum to 345 bar) |
| Operating Temperature | -320 to 752 °F (-196 to 400 °C) |
| Communication Protocol | 4-20 mA/HART™, Foundation™ Fieldbus, Modbus™ |
| Safety | SIL 2 IEC 61508 certification |
| TÜV tested and WHG approved for overfill prevention | |
| Remote proof-test capabilities through verification reflector | |
| Diagnostics | Enhanced diagnostics enabling proactive maintenance |
| Probe Types | Rigid single lead, Segmented single lead, Flexible single lead, Rigid twin lead, Flexible twin lead, Coaxial and large coaxial, PTFE coated probes, Vapor probe |
| Warranty | Up to five years |
Features
- Direct Switch Technology gives increased sensitivity, high reliability, and long measurement ranges
- Signal Quality Metrics gives you the ability to work proactively with your level instrumentation
- Probe End Projection offers greater level measurement reliability
- Dynamic Vapor Compensation for improved plant heat rate
- Verification reflector for remote proof-testing and unique level transmitter verification
- Ultra-thin layer detection through Peak-in-Peak technology
The Rosemount 3308 Wireless Level Transmitter facilitates the automation of level and interface measurements in locations that were previously unreachable. By automating processes that were not previously possible, you can achieve cost savings of up to 60%. The Rosemount 3308 provides numerous benefits, including simple installation without the need for wiring, no requirement for calibration, and resistance to fluctuating process conditions. With remote access to process data and improved diagnostics for predictive maintenance, the need for visual inspections is eliminated.
|
Specifications
|
|
|
|
± 0.12 in. (3 mm) |
| Repeatability | ± 0.08 in. (2 mm) |
| Measurement Range | Up to 56 ft (17 m) |
| Operating Pressure | Full vacuum to 580 psi (Full vacuum to 40 bar) |
| Operating Temperature | -40 to 302°F (-40 to 150°C) |
| Communication Protocol | WirelessHART® |
| Battery Life | 9 years @ 1 min update rate |
| Diagnostics | Enhanced diagnostics which enables proactive maintenance |
| Probe Types | Rigid single lead, Segmented single lead, Flexible single lead, Flexible twin lead, Coaxial, PTFE coated probes |
Features
- Direct Switch Technology gives increased sensitivity, high reliability, and long battery life
- Signal Quality Metrics offers you the ability to work proactively with your level instrumentation
- Native wireless can give you a better overview of your plant by automating applications that you have not been able to automate before
The Rosemount 3408 Non-Contacting Radar Level Transmitter is a versatile FMCW radar suitable for level measurement and overfill prevention in many industries, including chemical. Smart features save time and maximize efficiency for trouble-free operations, simplifying commissioning, operation and testing. Smart diagnostics help you proactively plan maintenance and optional Bluetooth® connectivity allows convenient configuration and maintenance. Manual or automatic verification at scheduled intervals can be conducted from the control room at any time without process interruptions. Perform proof-testing remotely and in-situ with onboard functionality. NAMUR type tested and third party certified to IEC61508 for use in safety critical applications.
| Specifications | |
|
|
Standard: ± 0.08 in. (± 2 mm) |
| Ultra accuracy: ± 0.04 in. (± 1mm) | |
| Measurement Range | 98 ft. (30 m), 49 ft. (15 m) for the IEC 61508 certified version |
| Operating Pressure | -15 to 363 psig (-1 to 25 bar) |
| Operating Temperature | -76 to 392 °F (-60 to 200 °C) |
| Power Supply | 12-35 VDC (30 VDC in Intrinsically Safe installations) |
| Communication Protocol | 4-20mA HART7®, optional Bluetooth® connectivity |
| Certifications/Approvals | ATEX/UKEX, IECEx, USA, Canadian, see full specs for complete list of certifications |
| Safety | IEC 61508 certified to SIL 2, Overfill prevention according to WHG/TÜV |
| Antenna Type | Process Seal, Lens Antenna, Atmospheric Temperature and Pressure Lens Antenna |
Features
- Lens antenna available for very small process fittings (3/4") and with optional bracket mount
- All PTFE wetted parts allow for use in harsh conditions, such as corrosive medias
- Convenient configuration and maintenance using optional Bluetooth technology
- Schedule automatic health checks and receive report with Smart Meter Verification
- Go back in time for troubleshooting or process insight with on-board data Historian
- Continuously monitor measurement health with Smart Diagnostics Suite allowing for preventive maintenance and reduced downtime
- Safe and simple proof-tests can be carried out from the control room without changing the actual level
The Rosemount™ 5408 Non-Contacting Radar Level Transmitter uses enhanced technology and Human Centered Design to deliver accurate, reliable measurements on both liquid and solid materials. Using two-wire FMCW technology the Rosemount 5408 deploys a continuous echo to maximize radar signal strength and produce a more robust and reliable measurement. Delivering ease-of-use at every touch point, the Rosemount 5408 uses an intuitive software interface to guide the operator through installation, commissioning, proof-testing and maintenance. Powerful onboard diagnostics suite proactively monitors transmitter health and alerts if there is an issue. Safety certified to IEC 61508 for SIL 2 applications, the Rosemount 5408:SIS reduces cost of risk, increases efficiency and protects people and the environment.
|
Specifications
|
|
|
|
Standard: ± 0.08 in. (± 2 mm) |
| Ultra accuracy: ± 0.04in. (± 1mm) | |
| Measurement Range | 492 ft (150m), 82 ft (25 m) for Rosemount 5408:SIS in Safety mode |
| Operating Pressure | -15 to 1450 psi (-1 to 100 bar) |
| Operating Temperature | -76 to +482 °F (-60 to +250 °C) |
| Power Supply | 4-20mA/HART: 12-42.4 VDC (12-30 VDC in Intrinsically Safe installations) |
| Communication Protocol | 4-20mA HART® (2-wire loop-powered), Foundation™ Fieldbus |
| Certifications/Approvals | ATEX, IECEx, USA, Canadian, 3-A, CRN, see full specs for complete list of certifications |
| Safety | IEC 61508 certified to SIL 2 |
| TÜV tested and WHG approved for overfill prevention | |
| Antenna type | Cone antenna, Process seal antenna, Parabolic antenna |
| Diagnostics | Enhanced diagnostics enabling proactive maintenance: Signal Quality Metrics, Smart Meter Verification |
| Warranty | Up to 10-year limited warranty |
Features
- 26 GHz FMCW with unique energy efficient chip, try our Frequency Selector to see if this is the right frequency for you.
- Low 12V dc lift-off voltage
- Immune to intermittent power loss
- Unique PTFE seal design eliminates the need for o-rings
- Model tailored to SIS requirements, certified to IEC 61508 SIL 2
- Solid measurement with unique solids algorithm
- Process seal antenna for applications with heavy condensation and aggressive medias. Also available with Tri Clamp connection.
- Smart Proof Test Package: Quick and easy periodic proof-testing with built-in wizards, offering step-by-step guidance, dynamic visualizations, and ability to save or print detailed reports.?
- Process seal antenna for applications with heavy condensation and aggressive medias. Also available with Tri Clamp connection.
- 3-A certified for hygienic applications
The Rosemount 2120 Level Switch provides easy to install, reliable level detection and control. 3rd party IEC61508 (SIL2) safety and hygienic certification with choice of outputs makes it suitable for a wide range of applications. It has no moving parts, needs no calibration and is virtually unaffected by process conditions. Adjustable switching delay prevents false switching in turbulent applications. Understand what is going on with your process- the visible heartbeat LED provides device status and health, and magnetic test point provides an easy-to-use functional test.
|
Specifications
|
|
|
|
Direct Load, PLC/PNP, Relay, 8/16 mA, NAMUR |
| Process Media Density | Minimum 37.5 lb/ft3 (600 kg/m3) |
| Viscosity | 0.2 to 10000 cP (centiPoise) |
| Operating Pressure | Full vacuum to 1450 psi (Full vacuum to 100 bar) |
| Operating Temperature | -40 to 302 °F (-40 to 150 °C) |
| Safety | SIL2 IEC 61508 certified |
| TÜV tested and WHG approved for overfill prevention | |
| Diagnostics | Electronic self-checking and condition monitoring |
Features
- Magnetic test point makes testing of the Rosemount 2120 easy
- Can be operated using the sun or battery as a power source with the 12Vdc option
- Fast drip fork design gives a quicker response time, especially with viscous liquids
- Adjustable switching delay enables easy handling of turbulent and splashing applications
- 3-A and EHEDG certificates for hygienic applications. Compliance with FDA and ASME-BPE standards
Rosemount 2130 Level Switch is developed for challenging applications, tough operating conditions and safety critical environments. Its robust construction and built-in powerful diagnostics will allow you to focus on the essential part - your plant. It is a plug-and-play device, which means that it is easy to install and does not require any advanced configuration or calibration. It is also virtually unaffected by process conditions, which makes its measurements extremely reliable. The Rosemount 2130 is SIL 2 certified for safety instrumented systems. It will make sure that you stay safe from overfill, while at the same time optimizing your tank usage.
|
Specifications
|
|
|
|
Full vacuum to 1450 psi (Full vacuum to 100 bar) |
| Operating Temperature | -94 to 500°F (-70 to 260°C) |
| Safety | SIL2 IEC 61508 certified |
| TÜV tested and WHG approved for overfill prevention | |
| Diagnostics | Electronic self-checking and condition monitoring |
| Warranty | Up to five years |
Features
- Equipped with fork health monitoring, the device realizes if maintenance is needed
- Magnetic test point makes proof testing of the Rosemount 2130 easy
- Adjustable switching delay enables easy handling of turbulent or splashing conditions
- Explosion-proof/flameproof, and intrinsically safe options available
- Fast drip fork design gives a quicker response time, especially with viscous liquids
The new Rosemount™ 2140 is the world's first wired HART® vibrating fork level detector for applications including overfill prevention, high and low level alarms, and pump protection. Providing reliable level detection of all liquids as well as sediments, the Rosemount 2140 offers greater ease-of-use and flexibility with smart diagnostics that continuously monitor electronic and mechanical device health, and a fully integrated remote proof-testing capability, helping to increase safety and efficiency of both plant and workers. The Rosemount 2140:SIS is certified to IEC 61508 (SIL 2) for safety-critical applications.
|
Specifications
|
|
|
|
Full vacuum to 1450 psig at 122 °F psi (100 barg at 50 °C) |
| Operating Temperature | -40 to 302 °F (-40 to 150 °C) as standard. -94 to 500 °F (-70 to 260 °C) as option |
| Certifications/Approvals | ATEX, IECEx, USA, Canadian, see full specs for complete list of certifications |
| Safety | IEC 61508 SIL 2 Certified |
| Diagnostics | Continuous electronic self-checking and condition monitoring. |
| Optional: Smart diagnostics suite: Frequency profiling, power advisory and configurable process alerts | |
| Optional: Functional / partial proof test. Only Rosemount 2140:SIS: Remote partial proof-test |
Features
- World's only wired HART vibrating fork level detector.
- Dry/wet switching optimized for many media types. Includes wet sand settings for managing tank and separator efficiency.
- Dry/wet switching reliability is maximized even when the media properties are unknown. Especially important in small tanks and pipes where levels may rapidly change.
- Detects issues which may indicate coating or corrosion of the fork, and corrosion from water ingress.
- Excellent diagnostics coverage enables true predictive maintenance.
- Ready-for-upgrade kits to future-proof investments.
The Rosemount 2160 Wireless Level Detector is ideal for hard to reach locations. It is suitable for high and low level alarms, overfill prevention systems, and pump control with self-checking features. Cost savings of up to 60% can be realized by automating your processes that you have not been able to automate before. With remote access to process data and enhanced diagnostics for predictive maintenance, visual inspections are a thing of the past. The Rosemount 2160 is designed for energy efficiency and uses a high quality battery for a long battery life. With a 1 min update rate, the battery can last up to 10 years. This detector provides improved site safety and reliable measurement with wireless communication.
|
Specifications
|
|
|
|
Full vacuum to 1450 psi (Full vacuum to 100 bar) |
| Operating Temperature | -94 to 500°F (-70 to 260°C) |
| Battery Life | 10 year @ 1 min update rate |
| Safety | TÜV tested and WHG approved for overfill prevention |
| Diagnostics | Electronic self-checking and condition monitoring |
Features
- World’s first wireless liquid level detector for reliable point level detection, extending the full benefits of PlantWeb® to previously inaccessible locations
- Fast drip fork design gives quicker response time, especially with viscous liquids
- Enhanced diagnostics alert you before contamination, corrosion, or damage to wetted parts become a problem
- The Rosemount 2160 has minimal installation rules and can therefore be fitted into most existing process connections