D - Series Flowrate Indicator / Monitor / Totalizer

Fluidwell provides a broad array of solutions, ranging from a simple totalizer to a robust flow rate monitor equipped with features such as flow curve linearization, flow rate monitoring, signal transmission, alarm and pulse outputs, as well as it has linearization to display the actual flowrate . 

The D-Series products come in a distinctive DIN panel mount housing and are specifically designed for safe area use. The durable IP66, IP67 (NEMA4X) front enclosure, constructed from die-cast aluminum, sets these indicators apart from others in the market. The D-Series is capable of enduring complete immersion and strong water jets, making it exceptionally resilient.

 


D014 is a DIN Panel mount - Flow rate Indicator / Totalizer with pulse signal output. The D014 is a panel mount indicator / transmitter to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The non-resettable accumulated total can register up to 11 digits and is backed-up in EEPROM memory every minute, just as the running total. Related to the accumulated total, a scaled pulse is generated for re-transmitting the count on the display.

More details

D013 is a DIN Panel mount - Flow rate Monitor / Totalizer with high / low alarm output. The D013 is a versatile, panel mount flow rate indicator and totalizer with continuous flow rate monitoring feature. It has one low flow rate and one high flow rate alarm value. If desired, an alarm ignore (delay) function can be set up to allow for an incorrect flow rate for a certain period of time.

More details

D010 is a DIN Panel mount - Flow rate Indicator with very large digits. The D010 is a panel mount indicator with large 26mm (1") high digits which displays the actual flow rate. The measuring and time unit to be displayed below the flow rate are simply selected through an alphanumeric configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user friendly solution! The configuration of K-factors or Span and number of decimals is done through software functions, without any sensitive dip-switches or trimmers.

More details

D012 is a DIN Panel mount - Flow rate Indicator / Totalizer and displays flow rate and total simultaneously. The D012 is a panel mount indicator to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however can not be reset to zero. The measuring unit to be displayed is simply selected through an alfa-numerical configuration menu. A weather proof and userfriendly solution since no adhesive labels have to be put on the outside of the enclosure.
 

 

More details

D011 is a DIN Panel mount - Totalizer with resettable total and non-resettable accumulated total . The D011 is a panel mount totalizer which displays the running total and accumulated total simultaneously. Total can be reset to zero by pressing the CLEAR button twice. A non-resettable accumulated total is available with eleven digits. The measuring unit to be displayed is simply selected through an alfa-numerical configuration menu. A weather proof and userfriendly solution since no adhesive labels have to be put on the outside of the enclosure.

More details

D016 is a DIN Panel mount - Flow rate Indicator / Totalizer with linearization and pulse signal output. The D016 is a panel mount indicator / transmitter with linearization to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however can not be reset to zero. In addition to the average K-Factor or Span, eight linearization points can be entered with there frequencies or values. The unit will interpolate between these points greatly enhancing accuracy in any flowrange. Even for very low frequency applications is catered for. This linearization affects all displayed information as well as the pulse output.

More details