F - Series Flowrate Indicator / Monitor / Differential Flow Computer

Fluidwell provides a broad array of solutions, ranging from a simple totalizer to a robust flow rate monitor equipped with features such as flow curve linearization, flow rate monitoring, signal transmission, alarm and pulse outputs, and temperature and pressure compensation for corrected volume.

The F-Series products come in a robust IP67 (NEMA4X) field mount enclosure and are suitable for both safe and hazardous area applications. Certified according to ATEX and IECEx by DEKRA, as well as according to CSA c-us and FM for use in Intrinsically Safe applications, the F-Series is resistant to harsh weather conditions (rain, snow, salty atmospheres) and temperatures ranging from -40°C/-40°F to +80°C/+178°F, without the need for expensive protective cabinets.

<iframe width="450" height="300" src="https://www.youtube.com/embed/QAgcFBfBUbI" title="F-Series: 1 indicator for any sensor" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe>


F010 is a Safe area / Intrinsically safe - Flow rate Indicator with with very large digits. The F010 is a local indicator with large 26mm (1") high digits which displays the actual flow rate. The measuring and time unit to be displayed below the flow rate are simply selected through an alphanumeric configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user-friendly solution! The configuration of K-factors or Span and number of decimals is done through software functions, without any sensitive DIP-switches or trimmers.
 

 

More details

F011 is a Safe area / Intrinsically safe - Totalizer with resettable total and non-resettable accumulated total. The F011 is a local indicator which displays the running total and accumulated total simultaneously. Total can be reset to zero by pressing the CLEAR button twice. The accumulated total can register up to 11 digits and is backed-up in EEPROM memory every minute, just as the running total. The measuring unit to be displayed is simply selected through an alphanumeric configuration menu. A weather proof and user-friendly solution as it has no adhesive labels have to be put on the outside of the enclosure.

More details

F012 is a Safe area / Intrinsically safe - Flow rate Indicator / Totalizer displays flow rate and total simultaneously. The F012 is our most popular model. This local indicator displays the actual flow rate, total and accumulated total. Total can be reset to zero by pressing the CLEAR button twice. The accumulated total can register up to 11 digits and is backed-up in EEPROM memory every minute, just as the running total.
On-screen engineering units are easily configured from a comprehensive selection.
 

 

More details

F013 is a safe area / Intrinsically safe - Flow rate Monitor / Totalizer with one high / low alarm output. The F013 is a versatile flow rate indicator and totalizer with continuous flow rate monitoring feature. It has one low flow rate and one high flow rate alarm value. If desired, an alarm ignore function can be set up to allow for an incorrect flow rate for a certain period of time. The display shows flow rate, total, accumulated total, alarm values and alarm messages. On-screen engineering units are easily configured from a comprehensive selection. A weather proof and user-friendly solution as it has no adhesive labels have to be put on the outside of the enclosure.
 

 

More details

F014 is a Safe area / Intrinsically safe - Flow rate Monitor / Totalizer with pulse output. The F014 is a local indicator / transmitter which displays the actual flow rate, total and accumulated total. A scaled pulse, related to the accumulated total is generated for re-transmitting the count on the display. Total can be reset to zero by pressing the CLEAR button twice. The accumulated total can register up to 11 digits and is backed-up in EEPROM memory every minute, just as the running total.
On-screen engineering units are easily configured from a comprehensive selection.
 

 

More details

F016 is a Safe area / Intrinsically safe - Flow rate Indicator / Totalizer with linearization and pulse output. The F016 is a local indicator / transmitter which displays the actual flow rate, total and accumulated total. In addition to the average K-Factor or Span, eight linearization points can be entered with their frequencies or values. The unit will interpolate between these points, greatly enhancing accuracy in any flow range, even for very low frequency applications. This linearization affects all displayed information as well as the pulse output. On-screen engineering units are easily configured from a comprehensive selection.

More details

F018 is a Safe area / Intrinsically safe - Flow rate Indicator / Totalizer with linearization, pulse/alarm and analog outputs and HART communication. The F018 is a local indicator / transmitter with linearization and continuous flow rate monitoring feature. It displays the actual linearized flow rate, resettable total and non-resettable accumulated total. The F-Series is known worldwide as a range of user-friendly indicators. The F018 is even more impressive. The HART communication allows you to communicate in an easy way with smart "DD enabled host" systems.
 
In addition to the average K-Factor or Span, fifteen linearization points can be entered with their frequencies or values. The unit will interpolate between these points greatly enhancing accuracy in any flow range, even for very low frequency applications. This linearization affects all displayed information as well as the signal outputs.
 

 

More details

F110 is a Safe area / Intrinsically safe - Flow rate Indicator / Totalizer, analog and pulse outputs with Modbus communication, analog and pulse outputs. The F110 flow transmitter is the most popular model in our range of flow rate indicators / totalizers, complete with pulse and analog output signals. Even demanding applications are catered for with our base unit configuration. Displays total and flow rate simultaneously and additional accumulated total. On-screen engineering units are easily configured from a comprehensive selection.

More details

F103 is a Weatherproof - Flow Logger / TotalizerThe versatile with linearization, analog and pulse outputs. The versatile F103 Flow Totalizer is your best choice for flow monitoring applications. It is perfect for new installations and to replace existing flow analyzers in the field. Its rugged construction, unique plug-and-play design and attractive pricing makes the F103 the perfect flow logger for liquid and gas flow measurement in Class I, Division 2 hazardous areas. It is the first F-Series with flow logging besides the various pulse and analog output signals. Even demanding applications are catered for with our base unit configuration.
 
The display shows flow rate and totals. A current day total (daily total) and 15 historical (previous) day totals can be enabled in the setup menu to be shown at the main display. On-screen engineering units can easily be configured from a comprehensive menu. The flow/data logging is optional available and when chosen, it replaces the basic 15 historical (previous) day totals. Each log contains the flow rate, total, acc. total, time stamp and log number. The log can be downloaded as .csv file with the free software tool.
 

 

More details

F111 is a Safe area / Intrinsically safe - Dual input Flow rate Indicator / Totalizer with two pulse output. The F111 incorporates two flow rate indicators / totalizers in one enclosure, including a pulse output for each flow. There is no relationship between the flows, even different pulse signal input types can be used.
For each flow, on-screen engineering units are easily configured from a comprehensive selection. The F111 can be set to show the selected information manually or with an automatic toggle function.
 
 

More details

F112 is a Flow rate Indicator / Totalizer with linearization, Modbus, analog and pulse outputs. The F112 is a versatile flow rate indicator / transmitter and totalizer with the ability to precisely linearize the flowmeter signal. In addition to the average K-Factor or Span, fifteen linearization points can be entered with their frequencies or values. The unit will interpolate between these points, greatly enhancing accuracy in any flow range, even for very low frequency applications. This linearization affects all displayed information as well as the output signals.
 
Displays total and flow rate simultaneously and additional accumulated total. On-screen engineering units are easily configured from a comprehensive selection.
 

 

More details

F113 is a Safe area / Intrinsically safe - Flow rate Indicator / Totalizer with with high / low alarms, analog and pulse outputs. The F113 is a versatile flow rate indicator / transmitter and totalizer with continuous flow rate monitoring feature. It has two low flow rate and two high flow rate alarm values. If desired, an alarm ignore function can be set up to allow for an incorrect flow rate for a certain period of time. Up to five outputs are available to transmit flow rate, alarm conditions and accumulated total.
 
The display shows flow rate, total, accumulated total, alarm values, alarm messages and status. On-screen engineering units are easily configured from a comprehensive selection.
 

 

More details

F114 is a Safe area / Intrinsically safe - Ratio Monitor / Totalizer with high / low alarms and analog outputs. The F114 flow computer calculates the actual ratio between two separate flows. It has one low ratio and one high ratio alarm value. Special precautions are taken to allow start-up problems and incorrect ratio readings for a certain period of time. Based on the location of the flowmeters, a selection can be made out of six different formulas.
 
The display shows the ratio, alarm values, flow rate A, total A and flow rate B, total B. On-screen engineering units are easily configured from a comprehensive selection. The ratio can be displayed as 1:__ or as a percentage.
 

 

More details

F115 is a Safe area / Intrinsically safe - Bi-directional Flow rate Indicator / Totalizer with analog, pulse signal and flow direction outputs. The F115 has been developed for applications where the direction of flow is an issue. It is required to offer two pulse signals from the flowmeter which are 90° or 270° degrees out of phase. In case of a reverse flow, the flow rate will be displayed as a negative value, the totalizers will count down and a switch output will be set. The pulse and analog outputs do reflect both flow directions. On-screen engineering units are easily configured from a comprehensive selection.

More details

F116 is a Safe area / Intrinsically safe - Differential / Sum Flow Computer with Modbus communication, analog and pulse outputs. The F116 flow computer has been developed to calculate differential / consumption or total volume. The usual difficulties encountered in such applications include: pulsating flows, very low consumption readings, vibration and high ambient temperatures. These are all well catered for in the design and operation of the F116. The pulse and analog outputs do reflect the calculated differential or sum value.
 
The display shows flow rate, total and accumulated total. On-screen engineering units are easily configured from a comprehensive selection.
 

 

More details

F118 is a Safe area / Intrinsically safe - Flow rate Monitor / Totalizer with linearization, high / low alarms, analog and pulse outputs. The F118 is a versatile flow rate indicator / transmitter and totalizer with the ability to precisely linearize the flowmeter signal. In addition to the average K-Factor or Span, ten linearization points can be entered with their frequencies or values. The unit will interpolate between these points, greatly enhancing accuracy in any flow range, even for very low frequency applications. Moreover, a continuous flow rate monitoring feature is available with high and low flow rate alarm values and up to three alarm outputs.
 
Flow rate and total are transmitted with an analog and scaled pulse output. The display shows flow rate, total, accumulated total, alarm values, alarm messages and status. On-screen engineering units are easily configured from a comprehensive selection.
 

 

More details

Advanced F119 is a Flow rate Indicator / Totalizer with receipt printer driver linearization, analog and pulse outputs. The F119 is an advanced Totalizer with the unique function to send a “print receipt” command to a printer. The configurable ticket printing can be set for (daily) totals or delivery tickets. The F119 provides very precise linearization of the flow meters signal. In addition to the average K-Factor or Span, fifteen linearization points can be entered with there frequencies or values. The unit will interpolate between these points greatly enhancing accuracy in any flowrange. Even for very low frequency applications is catered. This linearization effects all displayed information as well as the signal outputs.
 
Displays total and flow rate simultaneously and additional accumulated total. A current day total (daily total) and 15 historical (previous) day totals can be enabled in the setup menu to be shown at the main display. On-screen engineering units can easily be configured from a comprehensive menu.
 
 

More details

Advanced F126-EL is a Safe area / Intrinsically safe - Flow Computer for liquidswith temperature compensation for corrected volume. The F126-EL flow computer has been developed to calculate corrected liquid volume at normal conditions. The corrected volumetric flow is calculated by measuring the uncorrected volumetric flow and actual line temperature which is processed with the thermal expansion coefficient algorithm stored in the flow computer. The reference temperature can be defined as desired (e.g. 15°C, 20°C or 60°F).
 
The display shows the compensated flow rate, total, accumulated total and the actual line temperature. On-screen engineering units like Nm³ are easily configured from a comprehensive selection.
 
 

More details

Advanced F126-EG is a Safe area / Intrinsically safe - Flow Computer for gas with temperature and pressure compensation for corrected volume. The F126-EG flow computer has been developed to calculate corrected gas volume at normal conditions. The corrected volumetric flow is calculated by measuring the uncorrected volumetric flow, actual line temperature and pressure which are processed with the equations stored in the flow computer. A compressibility factor can be set to approach a real gas behavior. The reference conditions can be defined as desired (e.g. 15°C or 60°F and 1.013 bar).
 
The display shows the compensated flow rate, total, accumulated total and the actual line temperature and pressure. On-screen engineering units like Nm³ are easily configured from a comprehensive selection.
 
 

More details

Advanced F127 is a Safe area / Intrinsically safe - Differential Flow Computer for liquids with temperature compensation for corrected volume. The F127 flow computer has been developed to calculate corrected differential liquid volume at normal conditions. This is calculated by measuring the uncorrected volumetric flow and actual line temperature in both the supply and return line. These signals are processed with the thermal expansion coefficient algorithm stored in the flow computer. The reference temperature can be defined as desired (e.g. 15°C, 20°C or 60°F). The usual difficulties encountered in such applications include: pulsating flows, very low consumption readings, vibration and high ambient temperatures. These are all well catered for in the design and operation of the F127.
 
The display shows the compensated consumption / flow rate, total, accumulated total and actual line temperatures. On-screen engineering units like Nm³ are easily configured from a comprehensive selection.
 

 

More details